DAQ Testing/20181121
From PREX Wiki
Jump to navigationJump to searchBack to Main Page >> DAQ Documentation Portal >> DAQ Testing >> DAQ Commissioning Notes
Previous Day of Testing << >> Next Day of Testing
November 21st, 2018 Testers: Cameron
Goals
- Take data during MCC high current beam test
ROC 26 LHRS doesn't respond to telnet connections
- [apar@adaq3 ~]$ telnet hatsv21 2004
- Trying 129.57.192.16...
- Connected to hatsv21.
- Escape character is '^]'.
- Connection closed by foreign host.
Testing CntInj config
- Run 4643 - CODA runs noHRSs config and returns an error in ROC 24, doesn't get past event 4
- interrupt: scalRead: nvalues!=arg
- Run 4644 - CODA runs CntInj config and returns an error in ROC 24, takes normal data
- interrupt: scalRead: FIFO Empty
- interrupt: scalRead: nvalues!=arg
- Run 4645 - CODA runs noHRSs config (fixed to use the second crl info from the CntInj config) and still hangs at 4 events
- This probably isn't a problem, because we do have helicity information plugged into one channel of the FLEXIO scaler in the counting house, so we can reconstruct helicity correlated beam current asymmetries at high current, it will just take some work.
Results
- HALOG for the high current beam test
- Run 4642 is the standard current test
- Run 4643 is the high current test