20200511-Optics-Mtg
From PREX Wiki
Revision as of 15:40, 11 May 2020 by Kent Paschke (talk | contribs)
Back to Main Page >> HRS_Optics_Mtg
previous meeting << >> following meeting
Logistic information
Toll-Free Number (U.S.& Canada): 888-240-2560 PARTICIPANT CODE: # 585 129 220 Room IRL: <none>
Agenda
Please post slides in haplog or docdb, before the meeting
- Siyu - Dp shift check
- look at central value +/- error on parameter (not RMS) to get the error from the fit on the separation
- do this for each of the momentum settings (and ultimately, do this for each of the holes in the sieve)
- use error propagation to see how recoil energy difference or derived scattering angle depends on beam energy, scattering angle...
- Ryan:
- verifying the PREX database - Looking at Theta-Phi Optimization
- Kent
- more details about tasks for PREX and transverse asymmetry prelim results
Minutes
- Siyu
- estimates 1% bias in central angle from watercell, due to bias in carbon calibration data.
- Necessary to correct the field point using readback on magnet fields
- Could be caused by energy difference. Look at Right arm. Look at energy value from epics (get Devi's help for how to do this).
- May also need to keep track of beam position on target - corrections may be required for this (at least for watercell data).
- Will look into multiple measurements for both carbon and watercell.
- Ryan
- Finds significant residuals in available database for left arm... Siyu will make sure the final optimized database is available.
- Finds significant theta residuals, maybe due to error in residual calculation? Will check into it
- Next is to try to dp residuals also (when he gets optimized data base from Siyu)
- Eventually, should reproduce Q2 (semi-)independently
Attendence
Siyu, Ryan, Nilanga, Bob, Dustin, Devi, Chandan, Kent