DAQ Testing/20200804
From PREX Wiki
Jump to navigationJump to searchBack to Main Page >> DAQ Documentation Portal >> DAQ Testing >> DAQ Commissioning Notes
Previous Day of Testing << >> Next Day of Testing
August 4th, 2020 Tester: Cameron Clarke
Replacing VQWK number 025 from L:HRS _0_3 bad channel
To make these plots I have used the DAQ_Checkout.conf decoding configuration (for the CH_INJ CODA config) and used the panguin macro QualityAssurance/testChannels.cfg
- Run 7535 - Show the failure of ADC 032 channel 02, railed at -10 (as Victoria found a few days ago)
- Run 7536 - Show the old LHRS ADC 025 with non-linear response: https://logbooks.jlab.org/entry/3820478
Checking out all ADC modules
Using the RampAll config (rampdac16 setting in CH crate cedit config)
- Run 7537 - Looks good by eye, if interested see PDFs in ~/cameronc/DAQ-calibration/CREX-August-Restart/
- Run 7538-7544 : remaining 7 ADCs in CH crate, all appear good
- Run 7545 - added rampdac16 to L and RHRS in CEDIT - test run, works
- Run 7546 - LHRS test, turns out channel _3 has another problem, no negative voltage range and strange positive channels-volts scale factor -> Will replace with ADC 001
- Run 7547-7548 - RHRS tests, both ADCs good... SAM 5 has some 60 Hz noise that is affected by jostling cables... maybe removed now after replugging
- Run 7549 - LHRS test again, with ADC 001 this time, all good
HALOG entry: https://logbooks.jlab.org/entry/3820580#