WAC Notes August 16 2020

From PREX Wiki
Revision as of 03:59, 16 August 2020 by Cameronc (talk | contribs) (Created page with "=== Production Run List - Slug 190 - IHWP OUT - Flip-RIGHT === Continued from yeterday's run here ===='''Back to the OLD Moller quads tune''' - ''...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigationJump to search

Production Run List - Slug 190 - IHWP OUT - Flip-RIGHT

Continued from yeterday's run here

Back to the OLD Moller quads tune - Septum hadn't been cycled after hall work

  • Good - Run 7759 - Looks good.
    • 100 uA for most of the run.
    • First run back with the originally used Moller quad tune set up.
    • Noticed the SBS and HES septum magnet power supplies both weren't cycled correctly around noon and cycled them now.

RHRS Dipole tripped

  • Good - Run 7760 - Looks good
    • Cut out :70k events for large beam motion at the beginning of the run.
    • R dipole tripped -> Set RHRS main detectors to local cuts and no-blinding and no-normalization
  • Good - Run 7762 -
  • Good - Run 7763 -