DAQ Meeting/20180525

From PREX Wiki
Revision as of 23:35, 24 May 2018 by Cameronc (talk | contribs) (Created page with "Back to Main Page >> DAQ_Meeting previous meeting << >> following meeting == Logistic information ==...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigationJump to search

Back to Main Page >> DAQ_Meeting

previous meeting << >> following meeting

Logistic information

 BlueJeans calling instructions:
 Toll-Free Number (U.S.&  Canada):  888-240-2560
 International toll number:         408-740-7256
 Bluejeans CODE:                  475 839 391
 Bluejeans link: https://bluejeans.com/475839391

Agenda

  • Bob : Set up LHRS ROC and DAQ, add QWeak ADCs, connect to RHRS, and add to TS
    • Connect the trigger-in TTL signal from the T_Settle/MPS helicity NIM crate into the LHRS ROC 25, as well as into two new QWeak ADCs (NIM signal).
  • Bob : Finish setting up all DAQ components to Trigger Supervisor Control (TSC) and verify all components work as intended
    • Connect the flat RS45 cable number 21 between the L and R HRSs.
    • Make sure that the LHRS ROC connects to the ASAQ3 CODA in the counting house, and make sure that the ROC's hardware RAM ROC code is correctly set in Prex.crl.
      • First run the Prex.crl standalone.
      • Next connect TS control with the Prex_ts.crl (if possible, troubleshoot).
      • Then merge all of (LHRS->RHRS + Injector) -> Counting House all work together under TS control.
  • Long-range plan :
    • PAN, post-PAN and PAN-guin (Parity Analyze software) should all be rewritten, primarily to bring its functionality into the current group's control.

Minutes

  • Morning - 9AM - Chandan, Tyler, Cameron, Bob :