DAQ Meeting/20180525
From PREX Wiki
Revision as of 23:35, 24 May 2018 by Cameronc (talk | contribs) (Created page with "Back to Main Page >> DAQ_Meeting previous meeting << >> following meeting == Logistic information ==...")
Back to Main Page >> DAQ_Meeting
previous meeting << >> following meeting
Logistic information
BlueJeans calling instructions: Toll-Free Number (U.S.& Canada): 888-240-2560 International toll number: 408-740-7256 Bluejeans CODE: 475 839 391 Bluejeans link: https://bluejeans.com/475839391
Agenda
- Bob : Set up LHRS ROC and DAQ, add QWeak ADCs, connect to RHRS, and add to TS
- Connect the trigger-in TTL signal from the T_Settle/MPS helicity NIM crate into the LHRS ROC 25, as well as into two new QWeak ADCs (NIM signal).
- Bob : Finish setting up all DAQ components to Trigger Supervisor Control (TSC) and verify all components work as intended
- Connect the flat RS45 cable number 21 between the L and R HRSs.
- Make sure that the LHRS ROC connects to the ASAQ3 CODA in the counting house, and make sure that the ROC's hardware RAM ROC code is correctly set in Prex.crl.
- First run the Prex.crl standalone.
- Next connect TS control with the Prex_ts.crl (if possible, troubleshoot).
- Then merge all of (LHRS->RHRS + Injector) -> Counting House all work together under TS control.
- Long-range plan :
- PAN, post-PAN and PAN-guin (Parity Analyze software) should all be rewritten, primarily to bring its functionality into the current group's control.
Minutes
- Morning - 9AM - Chandan, Tyler, Cameron, Bob :