CODA

From PREX Wiki
Jump to navigationJump to search

Starting Parity DAQ CODA

Starting the GUI

Figure 1 - Main CODA window when first started.
Image 2
Image 3
  • Log in as apar@adaq1
  • In a terminal type startcoda
    • 4 xterms will appear as well as the main CODA window (see Figure 1)
    • CODA will automatically load the last configuration used. If you are ok with this then just go to Platform->Connect
  • To change the configuration, choose Configurations->Cool
    • Select the desired configuration from the dropdown list (see Figure 2)
    • Production running would be PREX
    • Once you have loaded a configuration, the

Starting a run

Description of the icons in the gui (any of the Figures)

    • Configure (the work tool icon at the top of the window; first at the left)
    • Download (second icon from the top left)
    • Prestart (third icon from the top left)
      • In the previous steps, warnings about waiting for a roc can be ignored if it does not take too long to respond (~10s). Do watch for Error messages. Those cannot be ignored!
  • Start (4th icon from the top left)
  • End (5th icon from the top left)

Instructions for shift checklist

  • Latest run type (Test, Physics,..)
  • Is the auto replay script running (ask the analysis expert)?
  • Is the PREX run list (in a white binder) completed? (are we going to do this?)
  • Please attach the left/right HV and Scalers Screenshots to the shift report
  • Time of beginning of latest run (RHRS)
  • Latest run number
  • Dead time (%)