HRS DAQ for Q2, Optics

From PREX Wiki
Revision as of 10:48, 20 June 2019 by Rom (talk | contribs)
Jump to navigationJump to search

The HRS DAQ is used for Optics, for measuring Qsq, and background studies. This is expert driven.

We will need a checklist for switching between counting mode and integrating mode. The old checklist is linked below. We'll need instructions which are at least as good:

https://hallaweb.jlab.org/parity/prex/runinfo/check_spectdaq.html

L-HRS DAQ runs on adaq3 ........ R-HRS DAQ runs on adaq2

Account: adaq

CODA will normally be running already. But, to start CODA from scratch on either HRS: "startcoda"

The running config is usually LeftHRS or Righthrs, but there may be other configs for special purposes.

Triggers are (still to be defined)

T1: S0 scintillator T2: S3 scintillator (behind Quartz) T3, T4, etc.

How to set Prescale factors: Type "prescaleL" or "prescaleR" and use the obvious GUI.

Scalers display (xscaler): Login to aonl1 as the a-onl account and type "xscaler", then do what it says to do. Note that xscaler is normally running on the hapc3 computer above the adaq1 console.

 
Triggers for PREX

T1 = S0A & S0B
T2 = S3
T3 = S0A || S0B
T4 = Upstream Quartz
T5 = Downstream Quartz
T6 = ((S0A & S0B) & S3) = T1.and.T2
T8 = Clock (1024 Hz)

Note about prescale factors
Max prescale factors: ps1-4=16777215; ps5-8=65535
T9-12 cannot be prescaled but any trigger can be turned off with ps=0