This page details the checklists for recovery of power outage. The following things has to be checked:
Checklist for power outage recovery
- VME/NIM crates are on
- VDC threshold (3 V) power supplies are on
- GEM low voltage power supplies are on
- Gas flow is working on both arms for VDCs and GEM detectors
- HV crates (LeCroy and GEM) are on
- If linear FIFO is used, check their base line (these values shift after power power recycle). If base line is changed above zero, adjust it and check for discriminator threshold
- Check if motion system is working as expected