WAC Notes January 11 2020

From PREX Wiki
Revision as of 11:19, 11 January 2020 by Cameronc (talk | contribs) (Created page with "{| cellpadding=5 style="margin:7px 30px 0 30px; <!-- --> float:right; border:1px solid #AA6633" |- bgcolor="#fbfeff" |- |Documentation |- | HOW TOs | HOW TOs for shif...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigationJump to search
Documentation
HOW TOs for shift crew
Expert Tools
All Expert Contacts



PREX Main << Weekly Analysis Coordinator << WAC Notes << Instructions

WAC Notes January 9 2020 << >> WAC Notes January 12 2020

January 11 2020

Daily Meeting BlueJeans

Production Run List - Slug 106 (b) - Production

  • Good - Run 5636 - Ca48 150uA - very messy beam, otherwise OK small amount of data


Non-Production Runs and Bad Runs

Pedestal/Calibrations Updates

Issues

BMOD Ana

note regarding beammod analysis:

Running the BeamMod analysis for a single run.

From ~/PREX/prompt/bmodAna/ create a new beammod root file from the already prompted run (####) using command root -l -b -q bmodAna.C'(####,"some_input.list")'

then, to plot all combinations of alphas, deltas,and alpha/delta use the common root -l -b -q plotAD.C'("path/to/rootfile/created/by/the/previous/command.root")

Counting Mode Downstream Detectors

  • Removed from cuts and correlator channel maps for safety