20180731-Radiation-Mtg

From PREX Wiki
Revision as of 11:46, 31 July 2018 by Ciprian Gal (Talk | contribs)

Jump to: navigation, search

Back to Main Page >> Radiation_Mtg

previous meeting << >> following meeting

Logistic information

 BlueJeans calling instructions:
   Toll-Free Number (U.S.&  Canada):  888-240-2560
   International toll number:         408-740-7256
   PARTICIPANT CODE:                  https://bluejeans.com/190761523


Agenda / Minutes

  1. Cameron: SAM sims
    • CC: will present tomorrow with an update for the no SAM configuration but with 5 cm upstream target
    • KP: we should take care of the raster as well. CG: once we get the optics information from Yves we will update the main sim and port the information to Cameron's version
  2. Ciprian: thermal neutrons slides
    • CG: it looks like the thermals are at the HRS are significantly smaller than during PREX1. For the collimator region the concrete shielding is very important and can provide significant improvement on the thermal numbers for PREX2. There does not seem to be a significant difference between 5% Boron or 50% Boron

Attendance

Ciprian G, Victoria O, Kent P, David A, Cameron C,

Excused:

Adam Z