Detailed High current plan
From PREX Wiki
Beamline instrumentation calibration
- Check detector alignment and pulse height (Done)
- 1uA cavity lock
- 0.2% Carbon
- 20 nA, cavity locks on and cavities in low current mode
- VDC on.
- Check rates, verify pulse height spectra and alignment
- Modify DAQ to include GEMS. 10 minute run with GEMS.
- C-Hole target, verify spot (Done)
- 20 nA, spot ++ verify raster size
- harp scan 4e, verify intrinsic size at target
- High current - no target (Skip it tonight)
- verify compton rates
- Ramp to SAM Shutter test
- Insert Lead Target.
- Raster 10x10.
- 20 nA. (Atten 107, slit 15)
- Cav locks on
- spot++ verify not seeing edges
- Set raster ?x? (to get (x.y) = 4x6 real)
- go up in current 1uA (5min)
- All HV off in HRS hut
- Target lock (0.6mm, 0.4mm)
- Collimator water temp
- beamline temperatures
- Ion chamber (stability)
- SAM yields
- BCM and BPM yields, widths.
- Insert Lead Target.
- access to remove SAM shutters, detector to integrate mode.
- Ramp to hi current test.
- cavity bpm back to high current mode
- All HV off in HRS hut, except quartz
- Target lock (0.6mm, 0.4mm)
- 5uA (review) (10min)
- Target lock, FFB (monitor bpm SAT)
- Collimator water temp
- beamline temperatures
- Ion chamber (stability)
- SAM and DET yields and widths
- BCM and BPM yields, widths.
- 20uA (review) (10min)
- Target lock, FFB (monitor bpm SAT)
- Collimator water temp
- beamline temperatures
- Ion chamber (stability)
- SAM and DET yields and widths
- BCM and BPM yields, widths.
- 40-50A(1hr)
- Target lock, FFB (monitor bpm SAT)
- Aq feedback
- Collimator water temp
- beamline temperatures
- Ion chamber (stability)
- SAM and DET yields and widths
- BCM and BPM yields, widths.
- Calibration scan
- FFB ON
- to 40-50uA
- SAMs HVs set
- DETs HVs set
- PITA scan at end to check det linearities later
- BMW
- tune beam, slow lock on (ad FFB on?), exercise BMW, check no ion chamber trips, check pauses locks and FFB
- low current 2-3uA, exercise BMW, check BPM signals, check no ion chamber issues
- target in, low current 2-3uA,exercise BMW, check BPM signals, check no ion chamber issues
- "ready for high current"
- Check the following has been performed
- 50uA-70uA beam current, through Compton (backgrounds on fingers and Compton photon detector) with no target
- Establish 4x4 raster. Insert lead target. (low current, ramp up. check collimator water, vary raster size 4x6?)
- Set Detector and SAM voltages (Dustin M)
- Check Conditions OK
- collimator water
- thermocouple temperatures
- radiation monitors
- ion chamber stability
- Setup Locks (these are necessary for main detectors and SAM calibration)
- Slow Target Lock on 4A, 4E (jmenu->"slow locks"-> Orbit Locks Expanded View -> HallATGT)
- Fast feedback for HallA on (iocse9)
- If beam is going through Compton, HallAComLock should probably be on
- Coordinate
- Should Compton and Moller DAQ be running during calibration?
- Dustin and Devi examining SAMs and Detectors with online analyzer during calibration
- Juan Carlos/Amali/Adam monitor Compton background rates and run the DAQ?
- Ye puts Cavity BPMs in high current mode (opsl01 -> menubar->EDM->BPM->BPM Diagnostics DR(12GeV)->HallA BCMs B,C,D -> button -> Expert Controls -> HWReg button -> DACSL1 = 0x1 / 0x1 and DACSL2 = 0x1 / 0x1 -> back out to previous screen XVGA2 = 0 and YVGA2 =0 (for low current do 0x0 and VGA2=30). Do for all 3 BPM Cavs.
- Calibration Procedure A: with UNSER
- start at 70uA for 1min (scandata1==value in BCM0l02)
- beam off
- wait for 5sec(for unser to equilibrate), take unser pedestal data point for 30sec (scandata1=0)
- beam on at 75uA
- check slow target lock is in position
- check FFB on for HallA
- check no bpms are saturated on iocse9
- wait for 5sec(for unser to equilibrate), take next data point for 1min
- repeat for 65uA,60uA,55uA,50uA,40uA,30uA,20uA,10uA
- Calibration Procedure B: with pre-calibrated Hall BCM (analog upstream bcm)
- start at 70uA for 1min (scandata1==value in BCM0l02)
- change current to 75uA
- check slow target lock is in position
- check FFB on for HallA
- check no bpms are saturated on iocse9
- take next 1min data point
- repeat for 65uA,60uA,55uA,50uA,40uA,30uA,20uA,10uA
- Calibration Procedure C: for BPMs (Compton bpms not yet calibrated)
- at 70uA, set gains off for iocse9,iocse10 (Hall) iocse11,iocse12,iocse19,iocinse4 (Inj)
- perform Calibration Procedure B with pre-calibrated Hall BCM