Difference between revisions of "HVgui"
From PREX Wiki
Chandabindu (Talk | contribs) |
|||
Line 7: | Line 7: | ||
== For shift workers == | == For shift workers == | ||
===To launch the HV GUI=== | ===To launch the HV GUI=== | ||
− | [[File: | + | [[File:Hvs_running_process.png|thumb|600px|right|Image 1]] |
*Log in as '''aslow@adaqsc''' (ask for password/probably no need of password) | *Log in as '''aslow@adaqsc''' (ask for password/probably no need of password) | ||
*cd into '''slowc''' directory | *cd into '''slowc''' directory | ||
− | *run '''./hvs | + | *run '''./hvs RIGHT''' for RHRS HV GUI |
− | *run '''./hvs | + | *run '''./hvs LEFT''' for LHRS HV GUI |
***Note: If the HV GUI is already running in some other computer, it will ask if you want to kill the running process (see Image 1). You can type '''y''' and hit '''Enter'''. This will just kill the pre-existing GUI but will not affect HV settings and status. | ***Note: If the HV GUI is already running in some other computer, it will ask if you want to kill the running process (see Image 1). You can type '''y''' and hit '''Enter'''. This will just kill the pre-existing GUI but will not affect HV settings and status. | ||
*Choose the desired slot | *Choose the desired slot | ||
===LHRS Detectors HV=== | ===LHRS Detectors HV=== | ||
− | [[File: | + | [[File:HV_GUi_pic.png|thumb|600px|right|Image 2:Values in the image are not necessarily the correct values]] |
*Make sure that the top left tab says '''rpi8''' (see Image 2) | *Make sure that the top left tab says '''rpi8''' (see Image 2) | ||
*To check '''scintillator''' HVs goto '''slot0 (i.e. S0)''' | *To check '''scintillator''' HVs goto '''slot0 (i.e. S0)''' | ||
Line 32: | Line 32: | ||
===RHRS Detectors HV=== | ===RHRS Detectors HV=== | ||
− | [[File: | + | [[File:HV_GUI_LEFT.png|thumb|600px|right|Image 3::Values in the image are not necessarily the correct values]] |
*Make sure that the top left tab says '''rpi4''' (see Image 3) | *Make sure that the top left tab says '''rpi4''' (see Image 3) | ||
*To check '''scintillator''' HVs goto '''slot0 (i.e. S0)''' | *To check '''scintillator''' HVs goto '''slot0 (i.e. S0)''' |
Revision as of 17:12, 25 June 2019
In the process of editing and updating this page. Please contact Juliette Mammei crowder@jlab.org with questions or suggestions.
PREX Main<< HOW TOs
Contents
For shift workers
To launch the HV GUI
- Log in as aslow@adaqsc (ask for password/probably no need of password)
- cd into slowc directory
- run ./hvs RIGHT for RHRS HV GUI
- run ./hvs LEFT for LHRS HV GUI
- Note: If the HV GUI is already running in some other computer, it will ask if you want to kill the running process (see Image 1). You can type y and hit Enter. This will just kill the pre-existing GUI but will not affect HV settings and status.
- Choose the desired slot
LHRS Detectors HV
- Make sure that the top left tab says rpi8 (see Image 2)
- To check scintillator HVs goto slot0 (i.e. S0)
- L0.0 channel is for S0A
- L0.1 channel is for S0B
- L0.2 channel is for S3
- To check Main and At detector HVs goto slot1 (i.e. S1)
- L1.0 channel is for UP-Quartz
- L1.1 channel is for DN-Quartz
- L1.2 channel is for AT-IN
- L1.3 channel is for AT-OUT
- To check VDC HVs goto slot7 (i.e. S7)
- L6.0 channel is for VDC1
- L6.3 channel is for VDC2
RHRS Detectors HV
- Make sure that the top left tab says rpi4 (see Image 3)
- To check scintillator HVs goto slot0 (i.e. S0)
- L0.0 channel is for S0A
- L0.1 channel is for S0B
- L0.2 channel is for S3
- To check Main and At detector HVs goto slot1 (i.e. S1)
- L1.0 channel is for UP-Quartz
- L1.1 channel is for DN-Quartz
- L1.2 channel is for AT-IN
- L1.3 channel is for AT-OUT
- To check SAM HVs goto slot4 (i.e. S4)
- L4.0 channel is for SAM1
- L4.1 channel is for SAM2
- L4.2 channel is for SAM3
- L4.3 channel is for SAM4
- L4.4 channel is for SAM5
- L4.5 channel is for SAM6
- L4.6 channel is for SAM7
- L4.7 channel is for SAM8
- To check VDC HVs goto slot14 (i.e. S14)
- L14.5 channel is for VDC1
- L14.7 channel is for VDC2