Difference between revisions of "WAC Notes August 27 2020"

From PREX Wiki
Jump to navigationJump to search
Line 25: Line 25:
 
* Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run8017_000 Run 8017]
 
* Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run8017_000 Run 8017]
 
* Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run8018_000 Run 8018]
 
* Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run8018_000 Run 8018]
* NeedCut - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run8019_000 Run 8019] -- large bpm12X excursion (minirun 2: reg_asym_us_avg.rms ~805 ppm)
+
* NeedCut - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run8019_000 Run 8019] -- large bpm12X excursion (minirun 2: reg_asym_us_avg.rms ~805 ppm). After cut, there are still some spikes, just leave them there now though the width is a little larger (but still < 800 ppm)
  
 
=== Production Run List - Slug 204 - IHWP OUT  - Flip-RIGHT - Production ===
 
=== Production Run List - Slug 204 - IHWP OUT  - Flip-RIGHT - Production ===

Revision as of 23:42, 31 August 2020

Documentation
HOW TOs for shift crew
Expert Tools
All Expert Contacts



PREX Main << Weekly Analysis Coordinator << WAC Notes CREX << Instructions

WAC Notes August 26 2020 << >> WAC Notes August 28 2020

August 27 2020

Daily Meeting BlueJeans

Production Run List - Slug 203 - IHWP IN - Flip-RIGHT - Production

  • Good - Run 8016
  • Good - Run 8017
  • Good - Run 8018
  • NeedCut - Run 8019 -- large bpm12X excursion (minirun 2: reg_asym_us_avg.rms ~805 ppm). After cut, there are still some spikes, just leave them there now though the width is a little larger (but still < 800 ppm)

Production Run List - Slug 204 - IHWP OUT - Flip-RIGHT - Production

Production Run List - Slug 205 - IHWP IN - Flip-RIGHT - Production

  • Good - Run 8031
  • Good - Run 8033
  • Good - Run 8035 -- an outlier in atr1, Entry$ == 28796, Device_Error_Code = 528
  • Good - Run 8036
  • Good - Run 8037
  • Good - Run 8038
  • Good - Run 8039
  • NeedCut - Run 8040 -- large bpm12X excursion, cut out some of them to bring down the reg_asym_us_avg rms; double peak in main detectors (not caused bu change of current), which is gone when cut out the large bpm12X excursion

Non-Production Runs and Bad Runs

Issues

Updates