WAC Notes February 5 2020

From PREX Wiki
Revision as of 22:06, 21 April 2020 by Weibin (Talk | contribs) (Production Run List - Slug 130 - IHWP IN - Flip-RIGHT - Production)

(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to: navigation, search
Documentation
HOW TOs for shift crew
Expert Tools
All Expert Contacts



PREX Main << Weekly Analysis Coordinator << WAC Notes CREX << Instructions

WAC Notes February 4 2020 << >> WAC Notes February 6 2020

February 5 2020

Daily Meeting BlueJeans


Production Run List - Slug 130 - IHWP IN - Flip-RIGHT - Production

continue slug 130 from February 4:

  • Good - Run 6211
  • Suspicious - Run 6212: FFB is turn off in the last 10 minutes, resulting in huge asym_bcm_an_us_mean, cut it? -- keep it currently
  • Good - Run 6213

Production Run List - Slug 131 - IHWP OUT - Flip-RIGHT - Production

  • Good - Run 6214 - Some large Aq laser noise, but the DDs look mostly OK, other than doing some up and down during the laser noise... OK
  • Good - Run 6215
  • Good - Run 6216: an outlier in atl2
  • Good - Run 6217
  • Good - Run 6218

INCOMPLETE

Non-Production Runs and Bad Runs

Pedestal/Calibrations Updates

Issues

  • the energy slope value (~35 ppm/um) is still smaller than previous value

Updates