Difference between revisions of "WAC Notes February 9 2020"
From PREX Wiki
m (→Updates) |
m (→Production Run List - Slug 133 - IHWP OUT - Flip-RIGHT - Production) |
||
Line 60: | Line 60: | ||
**BPM : Good. | **BPM : Good. | ||
**Detectors: Good. | **Detectors: Good. | ||
+ | **Later : BCM worries - 15 minute time scale BCM DD fluctuations, which don't seem to have a cause. Otherwise it's all good | ||
=== Production Run List - Slug 134 - IHWP IN - Flip-RIGHT - Production === | === Production Run List - Slug 134 - IHWP IN - Flip-RIGHT - Production === |
Revision as of 12:01, 31 March 2020
Documentation |
HOW TOs for shift crew |
Expert Tools |
All Expert Contacts |
PREX Main << Weekly Analysis Coordinator << WAC Notes CREX << Instructions
WAC Notes February 8 2020 << >> WAC Notes February 10 2020
Contents
February 9 2020
Daily Meeting BlueJeans
Production Run List - Slug 133 - IHWP OUT - Flip-RIGHT - Production
In general, detector slopes continue to get bigger and BCM widths continue to deteriorate in line with trend from the last slug
- Good - Run 6314
- Current : 150 uA
- BCM : Good. Width ~ 305.2 (excursion - bcm0l02)
- BPM : Good.
- Detectors: Good.
- Good - Run 6315
- Current : 150 uA
- BCM : Good. Width ~ 292.9
- BPM : Good.
- Detectors: Good.
- Good - Run 6316
- Current : 150 uA
- BCM : Good. Width ~ 326.4 (excursion - bcm0l02)
- BPM : Good.
- Detectors: Good.
- Good - Run 6317
- Current : 150 uA
- BCM : Good. Width ~ 290.7
- BPM : Good.
- Detectors: Good.
- Good - Run 6318
- Current : 150 uA
- BCM : Good. Width ~ 295.1
- BPM : Good.
- Detectors: Good.
- Good - Run 6319
- Current : 150 uA
- BCM : Good. Width ~ 294
- BPM : Good.
- Detectors: Good.
- Later : BCM worries - 15 minute time scale BCM DD fluctuations, which don't seem to have a cause. Otherwise it's all good
Production Run List - Slug 134 - IHWP IN - Flip-RIGHT - Production
- Good - Run 6320
- Current : 150 uA
- BCM : Good. Width ~ 285.9
- BPM : Good.
- Detectors: Good.
- Suspicious (Good after cutting out data post LQ1 trip) - Run 6321
- LQ1 trip https://logbooks.jlab.org/entry/3780677
- Current : 150 uA
- BCM : Good. Width ~ 280.8
- BPM : Good.
- Detectors: Good.
- Good but inefficient- Run 6322
- Current : 150 uA
- BCM : Good. Width ~ 263.1
- BPM : Good.
- Detectors: Good.
- Good but inefficient- Run 6323
- Current : 150 uA
- BCM : Good. Width ~ 251.7
- BPM : Good.
- Detectors: Good.
https://logbooks.jlab.org/entry/3780974
- Good - Run 6328
- Current : 150 uA
- BCM : Good. Width ~ 285.9
- BPM : Good.
- Detectors: Good.
- Good - Run 6329
- Current : 150 uA
- BCM : Good. Width ~ 279.2
- BPM : Good.
- Detectors: Good.
- Suspicious - 6330-6332 (charge feedback is not working)
- Need cuts - Run 6333
- Current : 150 uA
- BCM : Good. Width ~ 269.8
- BPM : Good. (single excursion)
- Detectors: Good.
- Good but inefficient - Run 6334
- Current : 150 uA
- BCM : Good. Width ~ 271
- BPM : Good.
- Detectors: Good.