WAC Notes January 25 2020

From PREX Wiki
Jump to navigationJump to search
The printable version is no longer supported and may have rendering errors. Please update your browser bookmarks and please use the default browser print function instead.
Documentation
HOW TOs for shift crew
Expert Tools
All Expert Contacts



PREX Main << Weekly Analysis Coordinator << WAC Notes CREX << Instructions

WAC Notes January 24 2020 << >> WAC Notes January 26 2020

January 25 2020

Daily Meeting BlueJeans

Production Run List - Slug 115 - Ca48 - IHWP IN

  • Good - Run 5915 - Calcium 48 production at last - cut BCM noisiness issue 0:40000 and 440000:
  • Good - Run 5916 - Cutting out 80000:162000 for BCM Aq issue
  • Good - Run 5917 - looks good. Cutting out 8000:40000 and 104000:152000 for BCM Aq issue
  • Good - Run 5918 - looks good. Cutting 16000:32000 for Aq blow up issue
  • Good - Run 5919 - Looks good


Production Run List - Slug 116 - Ca48 - IHWP OUT

  • Good - Run 5921 - Looks good
  • Good - Run 5922 - Looks good
  • Good - Run 5923 - Looks good
  • Good - Run 5924 - Main detectors moved x=-1.4mm both arms, looks good, some Aq clipping at the beginning, but OK

Production Run List - Slug 117 - Ca48 - IHWP OUT - detector alignment slug split

  • Good - Run 5928 - Post detector alignment. Some beam motion but its mostly fine.
  • Good - Run 5929 - Looks good
  • NeedCut/Decision - Run 5939 - Low Current.
  • NeedCut/Decision - Run 5940 - Low Current.

Non-Production Runs and Bad Runs

  • Burn in/Thermal commissioning - Run 5910 - Calcium 48 90 uA burn in
  • Burn in/Thermal commissioning - Run 5911 - Junk
  • Burn in/Thermal commissioning - Run 5912 - Calcium 48 60-120 uA burn in
  • Good Burn in/Thermal commissioning - Run 5913 - Calcium 48 120 uA burn in - data looks good
  • Good Burn in/Thermal commissioning - Run 5914 - Calcium 48 120 uA burn in - data looks good
  • Bad - Run 5920 - 120 uA, no Aq feedback, short run

Pedestal/Calibrations Updates

Issues

  • Restoring production on Calcium after target restoration. Target burn in, etc.
  • BMOD data is lacking from many runs, and some fix is needed to get properly useful data for these slugs after CREX II target is installed