Difference between revisions of "WAC Notes July 22 2019"
From PREX Wiki
(→Other Status Updates) |
(→Non-Production Runs and Bad Runs) |
||
(One intermediate revision by the same user not shown) | |||
Line 29: | Line 29: | ||
* Good - [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-21/run3569_000/run3569_000_all.pdf 3569] | * Good - [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-21/run3569_000/run3569_000_all.pdf 3569] | ||
* Good - [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-21/run3570_000/run3570_000_all.pdf 3570]: Aq ~ 0.5 ppm | * Good - [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-21/run3570_000/run3570_000_all.pdf 3570]: Aq ~ 0.5 ppm | ||
− | * Blinder failed, | + | * Good - Blinder failed, needed cuts - [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-21/run3571_000/run3571_000_all.pdf 3571]: Needs cuts to recover - got its cuts and its good |
* Good - [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-21/run3572_000/run3572_000_all.pdf 3572] | * Good - [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-21/run3572_000/run3572_000_all.pdf 3572] | ||
− | * | + | * Good - [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-21/run3573_000/run3573_000_all.pdf 3573]: Charge feedback went off for some events - needs cuts - it got its cuts and is OK now |
* Good - [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-22/run3574_000/run3574_000_all.pdf 3574]: BPM 12 slips during FFB off times | * Good - [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-22/run3574_000/run3574_000_all.pdf 3574]: BPM 12 slips during FFB off times | ||
* Good - [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-22/run3575_000/run3575_000_all.pdf 3575] | * Good - [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-22/run3575_000/run3575_000_all.pdf 3575] | ||
Line 39: | Line 39: | ||
* Dangerous Junk - [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-21/run3564_000/run3564_000_all.pdf 3564]: HVs off on left arm - don't analyze, as it will confuse and reveal blinder due to bad pedestals/null signal/blinding confusion | * Dangerous Junk - [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-21/run3564_000/run3564_000_all.pdf 3564]: HVs off on left arm - don't analyze, as it will confuse and reveal blinder due to bad pedestals/null signal/blinding confusion | ||
* Dangerous Junk - [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-21/run3565_000/run3565_000_all.pdf 3565]: "" | * Dangerous Junk - [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-21/run3565_000/run3565_000_all.pdf 3565]: "" | ||
− | * Blinder failed, | + | * Good - Blinder failed, needed cuts - [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-21/run3571_000/run3571_000_all.pdf 3571]: Needs cuts to recover - fixed |
− | * | + | * Good - Needed cuts - [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-21/run3573_000/run3573_000_all.pdf 3573]: Charge feedback went off for some events - needs cuts - fixed |
== Pedestal/Calibrations Updates == | == Pedestal/Calibrations Updates == |
Latest revision as of 20:37, 30 July 2019
Documentation |
HOW TOs for shift crew |
Expert Tools |
All Expert Contacts |
PREX Main << Weekly Analysis Coordinator << WAC Notes << Instructions
WAC Notes July 21 2019 << >> WAC Notes July 23 2019
Contents
July 22 2019
Production Run List Swing 2019/07/21 - 2019/07/22 Owl
Start Slug 11, IHWP Out, FFB on always, no RHRS on 3564, junk until 3566
- Dangerous Junk - 3564: HVs off on left arm - don't analyze, as it will confuse and reveal blinder due to bad pedestals/null signal/blinding confusion
- Dangerous Junk - 3565: ""
- Good - 3566: Begin production on slug 11, bcm width is quite large - 200 ppm, and minirun 4 has 185 USL ppm width, which is inexplicable as far as I can tell
- Good - 3567: large beam trip at end, BCM width got better this run
- Good - 3568
- Good - 3569
- Good - 3570: Aq ~ 0.5 ppm
- Good - Blinder failed, needed cuts - 3571: Needs cuts to recover - got its cuts and its good
- Good - 3572
- Good - 3573: Charge feedback went off for some events - needs cuts - it got its cuts and is OK now
- Good - 3574: BPM 12 slips during FFB off times
- Good - 3575
- Good - 3576
Non-Production Runs and Bad Runs
- Dangerous Junk - 3564: HVs off on left arm - don't analyze, as it will confuse and reveal blinder due to bad pedestals/null signal/blinding confusion
- Dangerous Junk - 3565: ""
- Good - Blinder failed, needed cuts - 3571: Needs cuts to recover - fixed
- Good - Needed cuts - 3573: Charge feedback went off for some events - needs cuts - fixed
Pedestal/Calibrations Updates
Issues
- There is slowness in the computer system - Ole thinks it has to do with a combination of heavy ethernet load, heavy Cache usage, and a poorly calibrated Scheduler
- Panguin as a test, 20x longer on adaq1, ps says its in nfs_wait mode
- logging all users out seems to fix it - (Cameron's theory is that ctrl+Z's processes were laying around everywhere and were occupying nfs file system attention that shouldn't have been)
- https://logbooks.jlab.org/entry/3708226, https://logbooks.jlab.org/entry/3708217, https://logbooks.jlab.org/entry/3708222
- Caryn is working on pedestal studies
- Caryn is also working on investigating Aq double peaking in the injector
- No beam all day due to LCW leak in west arc: HALOG
New Cuts
Applying detector Volts/uA cut to remove HV trips (LHRS 3564-3565) globally, and Quad mistunes and non-normalization (Slug 8->) locally
Looking at the effect of global, generous position yield cuts
Other Status Updates
- Accumulated charge = 11.33 Coulombs, 1.03 x PREX 1 statistical error bar
- Slug 11 is the final with the old PREX 1 quartz - from here on we are using different quartz: HALOG
- LHRS Counting Mode analyzer has major slowness
- It seems to be spending too much time in tracking
- Maybe a bad line in a db file?
- Actually it looks like the data itself is somehow difficult to parse / bad electronics, or some kind of power supply noise?
- Bob checks the electronics and it doesn't seem to be that... software/aonl?
- Its in PODD/the VDCs both!!
- Catherine has gone through permutations of BPM regression sets and has found that 11X is superior to 12X: HALOG, HAPLOG
- The RQ2 has some issues, largely to do with accumulated condensed/depositted/melted water around the quench detection circuit