WAC Notes July 24 2019
From PREX Wiki
The printable version is no longer supported and may have rendering errors. Please update your browser bookmarks and please use the default browser print function instead.
Documentation |
HOW TOs for shift crew |
Expert Tools |
All Expert Contacts |
PREX Main << Weekly Analysis Coordinator << WAC Notes << Instructions
WAC Notes July 23 2019 << >> WAC Notes July 25 2019
July 24 2019
Production Run List
Start Slug 12, IHWP In, FFB on always
- Good - run3595
- Good - run3596
- Bad - run3598
- rcdb says current scan but BCM yields are ~70uA, RMS on detectors look OK!
- 128 ppm charge asymmetry in BCMs, no Aq running ? -> There are 3 periods of different avg Aq, so maybe a cut will cut out the very large bad Aq stuff
- BPM 4ac still saturating and 4eX still 12 um widths
- Bad - run3601
- Mini-run 0 has ~4X RMS (det reg_asym). Note: Aq feedback off, RHWP rotated back to nominal value
- There is large BPM noise (20 um widths in the online plots, though it may be some strange outliers)
- Good - run3602
- Good - run3603
- Good - run3604
- Good - run3605
- Good - run3606
- Good - run3607
- Bad - run3608
- Not sure why the run was too short
- Too big Aq
Non-Production Runs and Bad Runs
- Junk run3589
- Junk run3590
- Junk run3591
- Test 50uA run3592
- Test 50uA run3593
- Test run @50uA large Aq mean
- Junk run3609
Pedestal/Calibrations Updates
- DET HV Calibration run3594
- Calibration - run3597
- RMS (after regression) is fluctuating between miniruns. Looks like current scan run!
- It is a current scan, bad Aq
- The BPM4ac is saturating the whole time
- The BPM 4eX is very wide (12 um widths)
- PITA Scan RHWP=500 run3599
- PITA Scan RHWP=500 run3600
- Aq feedback is off, very short run with elevated det width, big Aq mean
Issues
- Starting from the beginning of production running analysis fails all events without any indication why HALOG
- Analog BCMs are too noisey for recent runs HALOG
- Regression seems to be failing for run3604 run3605HALOG
- Double peaks and shoulders in bcm dd run3604 run3605 run3603 HALOG
- Residual correlation with AqDs3 run3605 run3604 run3603 run3602 run3601
- Seems all the runs have fluctuation on RMS on combined asymmetry (postpan).
Other Status Updates
- Accumulated charge = 12.65C
- Changed regression set (and added combined BPM 4a_4ec X) - git commit - HALOG
- new file: prex_combiner.3583-.map
- new file: prex_corrolator.3583-.conf
- Updated postpan regression "combo_reg.3583-.conf" - git commit 3f8fa67 (prompt repo commit aea4bb3), HALOG
- Added aggregator scripts to prompt repo - commit 6838abbbae9ca3e02a3a2d6e8d29050b5f9d2437
- Updated priliminary pedestal maps for 70uA running (for Main, AT, and SAM detectors) HALOG