Difference between revisions of "WAC Notes July 25 2019"

From PREX Wiki
Jump to: navigation, search
(Issues)
(Production Run List)
 
(32 intermediate revisions by the same user not shown)
Line 21: Line 21:
 
=== Production Run List ===
 
=== Production Run List ===
  
Start [https://hallaweb.jlab.org/parity/prex/onlinePlots/slug/slug_list/slug12-Left/y_postPanPlots_slug12-Left.pdf Slug 12, IHWP In, FFB on always, no RHRS]  
+
Start [https://hallaweb.jlab.org/parity/prex/onlinePlots/slug/slug_list/slug13/ Slug 13, IHWP OUT Flip Right, FFB on always]
* Good - [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-25/run####_000/run####_000_all.pdf ####]
+
***'''Since we are using bcm_dg_ds, the width in the bcm is ~1.5X of what we used to have with bcm_an_ds3'''
 +
* Good - [https://hallaweb.jlab.org/parity/prex/onlinePlots/index.php?run=summary/all/run3622_000 run3622]
 +
* Good - [https://hallaweb.jlab.org/parity/prex/onlinePlots/index.php?run=summary/all/run3623_000 run3623]
 +
* Good - [https://hallaweb.jlab.org/parity/prex/onlinePlots/index.php?run=summary/all/run3624_000 run3624]
 +
* Good - [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-25/run3625_000/ run3625]
 +
** Mini-run 0 had too large detector widths->'''Fixed after bad_event_cut'''
 +
* Good - [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-25/run3626_000 run3626]
 +
* Good - [https://hallaweb.jlab.org/parity/prex/onlinePlots/index.php?run=summary/all/run3629_000 run3629]
 +
** Aq mean was large for first two miniruns
 +
** bad_evt_cut applied, now good
 +
* Good - [https://hallaweb.jlab.org/parity/prex/onlinePlots/index.php?run=summary/all/run3630_000 run3630]'''ADDED from suspicious list'''
 +
** Detector widths are fluctuating between mini-runs.
 +
** First run with detector width started increasing
 +
** Applied bad_evt_cut, now good
 +
* Good - [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-25/run3631_000 run3631]'''ADDED from suspicious list'''
 +
** Detector widths become worse
 +
** Beam position change
 +
** Beam current fluctuating
 +
** Normalized detector yield is decreasing over time
 +
* Good - [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-26/run3632_000 run3632]'''ADDED from suspicious list'''
 +
** Regressed detector widths are even higher
 +
** Normalized detector yield is decreasing over time
 +
** Regressed detectors are correlated
 +
* Good - [https://hallaweb.jlab.org/parity/prex/onlinePlots/summary/2019-07-26/run3633_000 run3633]'''ADDED from suspicious list'''
 +
** Normalized detector yield is increasing over time (opposite to run3632)
 +
** Regressed detectors are correlated
 +
** Regressed detector widths are larger
 +
* Good - [https://hallaweb.jlab.org/parity/prex/onlinePlots/index.php?run=summary/all/run3634_000 run3634]'''ADDED from suspicious list'''
 +
** Normalized detector yield is increasing over time (opposite to run3632)
 +
** Regressed detectors are correlated
 +
** Regressed detector widths are larger
 +
* Good - [https://hallaweb.jlab.org/parity/prex/onlinePlots/index.php?run=summary/all/run3635_000 run3635]'''ADDED from suspicious list'''
 +
** Normalized detector yield is increasing over time (opposite to run3632)
 +
** Regressed detectors are correlated
 +
** Regressed detector widths are larger
 +
* Good - [https://hallaweb.jlab.org/parity/prex/onlinePlots/index.php?run=summary/all/run3636_000 run3636]'''ADDED from suspicious list'''
 +
** Long beam trip during the run
 +
** Normalized detector yield is decreasing again
 +
** Regressed detector widths are larger
 +
* Good - [https://hallaweb.jlab.org/parity/prex/onlinePlots/index.php?run=summary/all/run3640_000 run3640]'''ADDED from suspicious list'''
 +
** This run was taken during collimator scan
 +
** Aq widths are too large
 +
* Good - [https://hallaweb.jlab.org/parity/prex/onlinePlots/index.php?run=summary/all/run3641_000 run3641]'''ADDED from suspicious list'''
 +
** Aq widths are too large (>200ppm)
 +
** Started with 1uA checking position then go to 70uA
  
 
== Non-Production Runs and Bad Runs ==
 
== Non-Production Runs and Bad Runs ==
 +
* Test - [https://hallaweb.jlab.org/parity/prex/onlinePlots/index.php?run=summary/all/run3628_000 run3628]
  
 
== Pedestal/Calibrations Updates ==
 
== Pedestal/Calibrations Updates ==
Line 33: Line 78:
 
* The BCM appears to be falling apart. We are fixing it and running slug 12 on BCM DG DS in the meantime.
 
* The BCM appears to be falling apart. We are fixing it and running slug 12 on BCM DG DS in the meantime.
 
* BPM 4ec had intermittant problems (iocse10 has issues) and so we are regressing with 4e again. BPM 11X is ok and stays in regression.
 
* BPM 4ec had intermittant problems (iocse10 has issues) and so we are regressing with 4e again. BPM 11X is ok and stays in regression.
 +
 +
 +
* Increase in Detector widths and Collimator temperature [https://logbooks.jlab.org/entry/3710103 HALOG] [https://logbooks.jlab.org/entry/3709953 COLLIMATOR] [https://logbooks.jlab.org/entry/3710033 HALOG]
 +
* Increase in collimator temperature and raising neutron dose [https://logbooks.jlab.org/entry/3710012 HALOG]
 +
* The increase in detector widths started from late Swing Shift [https://logbooks.jlab.org/entry/3710003 HALOG]
 +
* Cavity BPM lock change [https://logbooks.jlab.org/entry/3710086 HALOG]
  
 
== Other Status Updates ==
 
== Other Status Updates ==

Latest revision as of 20:46, 6 August 2019

Documentation
HOW TOs for shift crew
Expert Tools
All Expert Contacts



PREX Main << Weekly Analysis Coordinator << WAC Notes << Instructions

WAC Notes July 24 2019 << >> WAC Notes July 26 2019

July 25 2019

Production Run List

Start Slug 13, IHWP OUT Flip Right, FFB on always

      • Since we are using bcm_dg_ds, the width in the bcm is ~1.5X of what we used to have with bcm_an_ds3
  • Good - run3622
  • Good - run3623
  • Good - run3624
  • Good - run3625
    • Mini-run 0 had too large detector widths->Fixed after bad_event_cut
  • Good - run3626
  • Good - run3629
    • Aq mean was large for first two miniruns
    • bad_evt_cut applied, now good
  • Good - run3630ADDED from suspicious list
    • Detector widths are fluctuating between mini-runs.
    • First run with detector width started increasing
    • Applied bad_evt_cut, now good
  • Good - run3631ADDED from suspicious list
    • Detector widths become worse
    • Beam position change
    • Beam current fluctuating
    • Normalized detector yield is decreasing over time
  • Good - run3632ADDED from suspicious list
    • Regressed detector widths are even higher
    • Normalized detector yield is decreasing over time
    • Regressed detectors are correlated
  • Good - run3633ADDED from suspicious list
    • Normalized detector yield is increasing over time (opposite to run3632)
    • Regressed detectors are correlated
    • Regressed detector widths are larger
  • Good - run3634ADDED from suspicious list
    • Normalized detector yield is increasing over time (opposite to run3632)
    • Regressed detectors are correlated
    • Regressed detector widths are larger
  • Good - run3635ADDED from suspicious list
    • Normalized detector yield is increasing over time (opposite to run3632)
    • Regressed detectors are correlated
    • Regressed detector widths are larger
  • Good - run3636ADDED from suspicious list
    • Long beam trip during the run
    • Normalized detector yield is decreasing again
    • Regressed detector widths are larger
  • Good - run3640ADDED from suspicious list
    • This run was taken during collimator scan
    • Aq widths are too large
  • Good - run3641ADDED from suspicious list
    • Aq widths are too large (>200ppm)
    • Started with 1uA checking position then go to 70uA

Non-Production Runs and Bad Runs

Pedestal/Calibrations Updates

Issues

  • There were many pedestal and event cut problems. From now on, when an event cut isn't absolutely necessary it should be removed - see japan source code for reference of cuts here
  • The BCM appears to be falling apart. We are fixing it and running slug 12 on BCM DG DS in the meantime.
  • BPM 4ec had intermittant problems (iocse10 has issues) and so we are regressing with 4e again. BPM 11X is ok and stays in regression.


  • Increase in Detector widths and Collimator temperature HALOG COLLIMATOR HALOG
  • Increase in collimator temperature and raising neutron dose HALOG
  • The increase in detector widths started from late Swing Shift HALOG
  • Cavity BPM lock change HALOG

Other Status Updates