Difference between revisions of "WAC Notes July 25 2019"
From PREX Wiki
(→Production Run List) |
(→Issues) |
||
Line 37: | Line 37: | ||
* The BCM appears to be falling apart. We are fixing it and running slug 12 on BCM DG DS in the meantime. | * The BCM appears to be falling apart. We are fixing it and running slug 12 on BCM DG DS in the meantime. | ||
* BPM 4ec had intermittant problems (iocse10 has issues) and so we are regressing with 4e again. BPM 11X is ok and stays in regression. | * BPM 4ec had intermittant problems (iocse10 has issues) and so we are regressing with 4e again. BPM 11X is ok and stays in regression. | ||
+ | |||
+ | |||
+ | * Increase in Detector widths and Collimator temperature | ||
== Other Status Updates == | == Other Status Updates == |
Revision as of 07:50, 26 July 2019
Documentation |
HOW TOs for shift crew |
Expert Tools |
All Expert Contacts |
PREX Main << Weekly Analysis Coordinator << WAC Notes << Instructions
WAC Notes July 24 2019 << >> WAC Notes July 26 2019
Contents
July 25 2019
Production Run List
Start Slug 13, IHWP OUT Flip Right, FFB on always
Non-Production Runs and Bad Runs
Pedestal/Calibrations Updates
Issues
- There were many pedestal and event cut problems. From now on, when an event cut isn't absolutely necessary it should be removed - see japan source code for reference of cuts here
- The BCM appears to be falling apart. We are fixing it and running slug 12 on BCM DG DS in the meantime.
- BPM 4ec had intermittant problems (iocse10 has issues) and so we are regressing with 4e again. BPM 11X is ok and stays in regression.
- Increase in Detector widths and Collimator temperature