WAC Notes July 26 2019

From PREX Wiki
Jump to navigationJump to search
The printable version is no longer supported and may have rendering errors. Please update your browser bookmarks and please use the default browser print function instead.
Documentation
HOW TOs for shift crew
Expert Tools
All Expert Contacts



PREX Main << Weekly Analysis Coordinator << WAC Notes << Instructions

WAC Notes July 25 2019 << >> WAC Notes July 27 2019

July 26 2019

Daily Meeting BlueJeans

Production Run List

Start Slug 14, IHWP In, FFB on always

      • Since we are using bcm_dg_ds, the width in the bcm asymmetry is 1.5X of what we had with bcm_an_ds
  • Suspicious - run3649
    • Short run with many beam trips
    • Caryn says "attempting to go to production but having some FFB issues"
  • Suspicious - run3650
    • BPM11 saturated
  • Suspicious - run3651
    • BPM11 saturated
  • Good run3652
  • Good run3653
    • Aq width is larger than normal

Non-Production Runs and Bad Runs

  • Test run3637
  • Test run3638
  • Test run3639
  • Test - run3640
    • This run was taken during collimator scan
    • Aq widths are too large
  • Test - run3641
    • Aq widths are too large (>200ppm)
    • Started with 1uA checking position then go to 70uA
    • Really a test run
  • Test run3642
  • Test run3643
    • Musson injects 10uA fake signal into digital system after new chassis added
  • Test run3644
    • Target Trouble Shooting
  • Test run3647
  • Attempting to production but some Feedback issue run3648

Pedestal/Calibrations Updates

Issues

Other Status Updates