Difference between revisions of "DAQ Testing/20190404"
From PREX Wiki
Jump to navigationJump to search(One intermediate revision by the same user not shown) | |||
Line 1: | Line 1: | ||
Back to [[Main_Page|Main Page]] >> [[DAQ_Doc_Portal|DAQ Documentation Portal]] >> [[DAQ_Testing|DAQ Testing]] >> [[DAQ_Commissioning_Notes|DAQ Commissioning Notes]] | Back to [[Main_Page|Main Page]] >> [[DAQ_Doc_Portal|DAQ Documentation Portal]] >> [[DAQ_Testing|DAQ Testing]] >> [[DAQ_Commissioning_Notes|DAQ Commissioning Notes]] | ||
− | [[DAQ_Testing/20190322|Previous Day of Testing]] << >> [[DAQ_Testing/ | + | [[DAQ_Testing/20190322|Previous Day of Testing]] << >> [[DAQ_Testing/20190429|Next Day of Testing]] |
April 4th, 2019 | April 4th, 2019 | ||
Line 20: | Line 20: | ||
/adaqfs/home/apar/coda26/cool/parity/config/Control/ALL_PREX/Processes | /adaqfs/home/apar/coda26/cool/parity/config/Control/ALL_PREX/Processes | ||
− | [[Category:DAQ_Testing | + | [[Category:DAQ_Testing]] |
Latest revision as of 11:57, 29 April 2019
Back to Main Page >> DAQ Documentation Portal >> DAQ Testing >> DAQ Commissioning Notes
Previous Day of Testing << >> Next Day of Testing
April 4th, 2019 Testers: Cameron Clarke
Goals
- Understand the counting house DAQ and make a point to point map
DAQ Status from APEX running
- The DAQ point to point map is documented here.
- The GMN2 signal was too late and the VQWK ADCs integrated into the subsequent TSettle window inappropriately, also see Caryn's note here which includes Beam Sync (relevant for moving to beam synched HelBoard settings).
Misc Notes
- In order to ensure that the cedit configs are reflected in translated databases look around in here:
/adaqfs/home/apar/coda26/cool/parity/config/Control/ALL_PREX/Processes