Difference between revisions of "WAC Notes August 31 2020"
From PREX Wiki
Jump to navigationJump to search (Created page with "{| cellpadding=5 style="margin:7px 30px 0 30px; <!-- --> float:right; border:1px solid #AA6633" |- bgcolor="#fbfeff" |- |Documentation |- | HOW TOs | HOW TOs for shif...") |
|||
(7 intermediate revisions by 2 users not shown) | |||
Line 21: | Line 21: | ||
'''Daily Meeting [https://bluejeans.com/454783784 BlueJeans]''' | '''Daily Meeting [https://bluejeans.com/454783784 BlueJeans]''' | ||
− | === Production Run List - Slug | + | === Production Run List - Slug 208 - IHWP IN - Flip-RIGHT - Production === |
− | * Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/ | + | we started slug 208 (delayed until IHWP flip happens) after slug 206, when slug 207 has finished before, so slug 207 and 208 have the same IHWP state |
− | + | * Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run8131_000 Run 8131] | |
− | + | * Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run8132_000 Run 8132] | |
+ | * Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run8133_000 Run 8133] | ||
+ | * Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run8134_000 Run 8134] | ||
+ | * Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run8135_000 Run 8135] | ||
+ | * Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run8136_000 Run 8136] | ||
+ | * Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run8137_000 Run 8137] | ||
+ | * Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run8138_000 Run 8138] | ||
+ | * Good - [https://prex.jlab.org/analysis/crex/index.php?run=summary/all/run8142_000 Run 8142] | ||
== Non-Production Runs and Bad Runs == | == Non-Production Runs and Bad Runs == | ||
− | * Junk - | + | * Junk - run 8139-8141 -- trying to restore beam |
− | |||
== Issues == | == Issues == | ||
+ | * beam was quite unstable, we have to go down to 135 uA | ||
+ | * Hall C failed to change pass due to problem in their target, so we come back to production in a rush. | ||
== Updates == | == Updates == | ||
− | + | * New pedestal files from yesterday Owl's pedestal running: https://logbooks.jlab.org/entry/3838542 | |
[[Category:WAC]] | [[Category:WAC]] |
Latest revision as of 08:21, 1 September 2020
Documentation |
HOW TOs for shift crew |
Expert Tools |
All Expert Contacts |
PREX Main << Weekly Analysis Coordinator << WAC Notes CREX << Instructions
WAC Notes August 30 2020 << >> WAC Notes September 1 2020
August 31 2020
Daily Meeting BlueJeans
Production Run List - Slug 208 - IHWP IN - Flip-RIGHT - Production
we started slug 208 (delayed until IHWP flip happens) after slug 206, when slug 207 has finished before, so slug 207 and 208 have the same IHWP state
- Good - Run 8131
- Good - Run 8132
- Good - Run 8133
- Good - Run 8134
- Good - Run 8135
- Good - Run 8136
- Good - Run 8137
- Good - Run 8138
- Good - Run 8142
Non-Production Runs and Bad Runs
- Junk - run 8139-8141 -- trying to restore beam
Issues
- beam was quite unstable, we have to go down to 135 uA
- Hall C failed to change pass due to problem in their target, so we come back to production in a rush.
Updates
- New pedestal files from yesterday Owl's pedestal running: https://logbooks.jlab.org/entry/3838542