Difference between revisions of "Full Shift Checklist"
From PREX Wiki
Jump to navigationJump to searchm |
|||
(13 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
<span style="color:red">In the process of editing and updating this page. Please contact Juliette Mammei <B>[mailto:crowder@jlab.org?Subject=PREXwiki crowder@jlab.org]</B> with questions or suggestions.</span> | <span style="color:red">In the process of editing and updating this page. Please contact Juliette Mammei <B>[mailto:crowder@jlab.org?Subject=PREXwiki crowder@jlab.org]</B> with questions or suggestions.</span> | ||
<br><br> | <br><br> | ||
− | [ | + | [[Main_Page|<B>PREX Main</B>]]<< [[Information for Shift Takers]] << [[Shift Checklist]] |
+ | <br> | ||
+ | |||
+ | This is just where I have documented changes to the shift checklist! Not really useful for anything else. | ||
+ | |||
+ | <br><br> | ||
+ | |||
+ | == Entering shift info == | ||
* Shift leader | * Shift leader | ||
* Target operator | * Target operator | ||
− | Analysis expert | + | * Analysis expert <span style="background-color:#F1C40F">Suggest remove</span> |
− | Shift (day, swing, or owl) | + | * Shift (day, swing, or owl) |
+ | ** Enter the names of the shift workers (Shift leader, Target operator, Analysis expert) <span style="background-color:#F1C40F">We don't require an Analysis Expert so we should remove it from here</span> | ||
+ | ** Indicate which shift the checklist is for (day, swing, or owl) | ||
+ | |||
+ | == [[Beam and Hall checks]] == | ||
+ | |||
+ | * Is alarm handler running on hacweb7? <span style="background-color:#F1C40F">Modify to: Is hall alarm handler running on hacweb7?</span> | ||
+ | * <span style="background-color:#F1C40F">Add: Is experimental alarm handler running on hacweb7?</span> | ||
+ | * Beam Energy (GeV) <span style="background-color:#F1C40F">Suggest remove</span> | ||
+ | * Beam current (µA) | ||
+ | * Downstream raster (B) on? Yes/No | ||
+ | * Raster size (x:y mm, see log 3654466 )? | ||
+ | * Fast feedback on? Yes/No | ||
+ | * Beam Position Monitor X/Y (mm) A | ||
+ | * Beam Position Monitor X/Y (mm) E (BPM B in Hall A Tools) | ||
+ | * <span style="background-color:#F1C40F">Add: Are Compton slow locks functioning?</span> | ||
+ | * <span style="background-color:#F1C40F">Add: Are target slow locks functioning?</span> | ||
+ | * <span style="background-color:#F1C40F">Add: Is the energy lock on?</span> | ||
+ | * BCM temperature (K) (PV, PS, Thermocouple) If these differ by +/-.5 from (110.0,110.0,115.0) make halog entry and contact RC | ||
+ | * Arc energy NMR locked? ( (Goto ARC or the "Field Management Screen", and verify if the box locked is ON/OFF)) | ||
+ | * Current Target | ||
+ | * Argon pressure (psi) | ||
+ | * Ethane pressure (psi) | ||
+ | * CO2 pressure (psi) | ||
+ | * Visual Hall Inspection OK? | ||
+ | * <del> Truck ramp door closed ( use the camera to see the door from mirror)? </del> * <span style="background-color:#F1C40F">Suggest remove</span> | ||
+ | * Septum current (A) and polarity? | ||
+ | * Upstream/downstream corrector currents (A) ? * <span style="background-color:#F1C40F">Suggest remove: we don't have correctors for our septum</span> | ||
+ | |||
+ | == [[Parity Checks]] == | ||
+ | |||
+ | * <span style="color:blue"> IHWP setting (IN/OUT) </span> | ||
+ | ** <span style="color:blue"> the button that is depressed is the setting </span> <span style="background-color:#F1C40F">I assume these are instructions (looks ok).</span> | ||
+ | ** <span style="color:blue"> PGUN and parity controls </span> <span style="background-color:#F1C40F">Do you want something specific from here?</span> | ||
+ | * <span style="color:blue"> RHWP setting (value like 1532) </span> | ||
+ | * <span style="color:blue"> Wien settings? </span> | ||
+ | ** <span style="color:blue"> Spin controls - jmenu search for spin </span> <span style="background-color:#F1C40F">I assume these are instructions (looks ok).</span> | ||
+ | ** <span style="color:blue"> VWienAngle </span> | ||
+ | ** <span style="color:blue"> Phi_FG </span> | ||
+ | ** <span style="color:blue"> HWienAngle </span> | ||
+ | ** <span style="color:blue"> FLIP(-LEFT) (-RIGHT) </span> | ||
+ | * <span style="color:blue">SAM HV</span> | ||
+ | * <span style="color:blue">Septum HV</span> <span style="background-color:#F1C40F">Add</span> | ||
+ | |||
+ | == [[Left Arm Checks]] == | ||
+ | |||
+ | * Left Arm momentum (GeV) | ||
+ | * Left Arm Q1, Q2, D, Q3 regulartors on (yes/no, ask experts)? <span style="background-color:#F1C40F">Suggest removing "on" since it hints that we need it on and I think we won't use them because they are set to momentum.</span> | ||
+ | * Left Arm cryo flow level OK? Yes/No He>60% (Ignore Nitrogen) | ||
+ | * Left Arm NMR OK? Yes/No | ||
+ | * Left Arm Q1 Momentum (GeV/c) / current (A) / B-Field (+/-G) | ||
+ | * Left Arm Q2 Momentum (GeV/c) / current (A) / B-Field (+/-G) | ||
+ | * Left Arm D Momentum (GeV/c) / current (A) / B-Field (+/-G) | ||
+ | * Left Arm Q3 Momentum (GeV/c) / current (A) / B-Field (+/-G) | ||
+ | * Is Left VDC gas flow (top/bottom) on? | ||
+ | * Left VDC HV on (top/bottom)?<span style="color:blue"> (off normally)</span> | ||
+ | * VDC thresholds (All 4 values should be 3.0 V, yes/no) <span style="color:blue"> (off normally)</span> | ||
+ | * <del> Left Cerenkov HV on? </del> <span style="background-color:#F1C40F">Agreed</span> | ||
+ | * <del> Left Pion rejector HV on? </del> <span style="background-color:#F1C40F">Agreed</span> | ||
+ | * <span style="color:blue"> Main Detector HV </span> | ||
+ | * <span style="color:blue"> GEM HV</span> <span style="background-color:#F1C40F">Add "normally off"</span> | ||
+ | * Left s0/s2m HV on (s0 may be off for production, check with expert)? | ||
+ | * Check online plots (y/n)? -LHRS | ||
+ | |||
+ | == [[Right Arm Checks]] == | ||
+ | <span style="background-color:#F1C40F">Similar to Left arm</span> | ||
+ | * Right arm momentum (GeV) | ||
+ | * Right Arm Q1, Q2,D,Q3 regulartor on? (yes/no) | ||
+ | * Right arm cryo flow level OK? Yes/No He>60% (Ignore Nitrogen) | ||
+ | * Right Arm NMR OK? Yes/No | ||
+ | * Right Arm Q1 Momentum (GeV/c) / current (A) / B-Field (+/-G) | ||
+ | * Right Arm Q2 Momentum (GeV/c) / current (A) / B-Field (+/-G) | ||
+ | * Right Arm D Momentum (GeV/c) / current (A) / B-Field (+/-G) | ||
+ | * Right Arm Q3 Momentum (GeV/c) / current (A) / B-Field (+/-G) | ||
+ | * Is Right VDC gas flow (top/bottom) on? | ||
+ | * Right VDC HV on (top/bottom)? <span style="color:blue"> (off normally)</span> | ||
+ | * <del> Right Cerenkov HV on? </del> | ||
+ | * <del> Right Pion rejector HV on? </del> | ||
+ | * Right s0/s2m HV on? | ||
+ | * <span style="color:blue"> Main Detector HV </span> | ||
+ | * <span style="color:blue"> GEM HV</span> | ||
+ | * <del> Right SCIFI HV off (should be off during production runs, y/n)?</del> | ||
+ | * <del> S3 HV off (ch 6 of SCIFI HV GUI, should be off for production)? </del> | ||
+ | * Check online plots (y/n)? -RHRS | ||
+ | |||
+ | == [[CODA#Instructions for shift checklist|CODA]] == | ||
− | Is | + | * Latest run type (Test, Physics,..) |
− | Is the | + | * Is the auto replay script running (ask the analysis expert)? |
+ | * <del>Is the APEX run list (in a white binder) completed?</del> <span style="background-color:#F1C40F">Agreed</span> | ||
+ | * <del>Please attach the left/right HV and Scalers Screenshots to the shift report</del> <span style="background-color:#F1C40F">Suggest to modify to: Attach Hall A Tools screenshot, Septum Power supply screenshot, Septum pipe temperature screenshots, Collimator water temperature screen shots to shift report.</span> | ||
+ | * <span style="color:blue"> Check scalers</span> <span style="background-color:#F1C40F">Not sure we will keep the scalers during regular production running.</span> | ||
+ | * Time of beginning of latest run (RHRS) <span style="background-color:#F1C40F">Modify (RHRS) to Integrating DAQ</span> | ||
+ | * Latest run number | ||
+ | * <del>Dead time (%)</del> <span style="background-color:#F1C40F">Agreed</span> | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | + | == [[BTA|Beamtime accounting]] == | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | + | * Beamtime accounting table submitted? <span style="background-color:#F1C40F">Generally this is done one hour before the end of shift so I am not sure how useful it is. Unless we want them to check this at the very end of the run; but that runs into the issue that they already took ~7h of data (possibility with problems).</span> | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | + | == In counting house == | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | Empty drip tray and place mug under spout on coffee maker | + | * <span style="color:blue">Is the volume up on hacweb7? (both hardware and software) </span> |
+ | * <span style="color:blue">VESDA System OK? (VESDA is the smoke/fire detection and alarm system. Check the Hall A VESDA Console on the wall beside the door to the compter room </span> | ||
+ | * Empty drip tray and place mug under spout on coffee maker | ||
+ | ** Press the buttons on either side of the tray and pull toward you | ||
+ | ** Place a mug under the spout while emptying the tray (and the previous mug) in the bathroom sink | ||
+ | ** Replace the tray by sliding back into the machine | ||
+ | ** Place a mug under the spout to help keep the tray from overflowing |
Latest revision as of 10:32, 11 July 2019
In the process of editing and updating this page. Please contact Juliette Mammei crowder@jlab.org with questions or suggestions.
PREX Main<< Information for Shift Takers << Shift Checklist
This is just where I have documented changes to the shift checklist! Not really useful for anything else.
Entering shift info
- Shift leader
- Target operator
- Analysis expert Suggest remove
- Shift (day, swing, or owl)
- Enter the names of the shift workers (Shift leader, Target operator, Analysis expert) We don't require an Analysis Expert so we should remove it from here
- Indicate which shift the checklist is for (day, swing, or owl)
Beam and Hall checks
- Is alarm handler running on hacweb7? Modify to: Is hall alarm handler running on hacweb7?
- Add: Is experimental alarm handler running on hacweb7?
- Beam Energy (GeV) Suggest remove
- Beam current (µA)
- Downstream raster (B) on? Yes/No
- Raster size (x:y mm, see log 3654466 )?
- Fast feedback on? Yes/No
- Beam Position Monitor X/Y (mm) A
- Beam Position Monitor X/Y (mm) E (BPM B in Hall A Tools)
- Add: Are Compton slow locks functioning?
- Add: Are target slow locks functioning?
- Add: Is the energy lock on?
- BCM temperature (K) (PV, PS, Thermocouple) If these differ by +/-.5 from (110.0,110.0,115.0) make halog entry and contact RC
- Arc energy NMR locked? ( (Goto ARC or the "Field Management Screen", and verify if the box locked is ON/OFF))
- Current Target
- Argon pressure (psi)
- Ethane pressure (psi)
- CO2 pressure (psi)
- Visual Hall Inspection OK?
Truck ramp door closed ( use the camera to see the door from mirror)?* Suggest remove- Septum current (A) and polarity?
- Upstream/downstream corrector currents (A) ? * Suggest remove: we don't have correctors for our septum
Parity Checks
- IHWP setting (IN/OUT)
- the button that is depressed is the setting I assume these are instructions (looks ok).
- PGUN and parity controls Do you want something specific from here?
- RHWP setting (value like 1532)
- Wien settings?
- Spin controls - jmenu search for spin I assume these are instructions (looks ok).
- VWienAngle
- Phi_FG
- HWienAngle
- FLIP(-LEFT) (-RIGHT)
- SAM HV
- Septum HV Add
Left Arm Checks
- Left Arm momentum (GeV)
- Left Arm Q1, Q2, D, Q3 regulartors on (yes/no, ask experts)? Suggest removing "on" since it hints that we need it on and I think we won't use them because they are set to momentum.
- Left Arm cryo flow level OK? Yes/No He>60% (Ignore Nitrogen)
- Left Arm NMR OK? Yes/No
- Left Arm Q1 Momentum (GeV/c) / current (A) / B-Field (+/-G)
- Left Arm Q2 Momentum (GeV/c) / current (A) / B-Field (+/-G)
- Left Arm D Momentum (GeV/c) / current (A) / B-Field (+/-G)
- Left Arm Q3 Momentum (GeV/c) / current (A) / B-Field (+/-G)
- Is Left VDC gas flow (top/bottom) on?
- Left VDC HV on (top/bottom)? (off normally)
- VDC thresholds (All 4 values should be 3.0 V, yes/no) (off normally)
Left Cerenkov HV on?AgreedLeft Pion rejector HV on?Agreed- Main Detector HV
- GEM HV Add "normally off"
- Left s0/s2m HV on (s0 may be off for production, check with expert)?
- Check online plots (y/n)? -LHRS
Right Arm Checks
Similar to Left arm
- Right arm momentum (GeV)
- Right Arm Q1, Q2,D,Q3 regulartor on? (yes/no)
- Right arm cryo flow level OK? Yes/No He>60% (Ignore Nitrogen)
- Right Arm NMR OK? Yes/No
- Right Arm Q1 Momentum (GeV/c) / current (A) / B-Field (+/-G)
- Right Arm Q2 Momentum (GeV/c) / current (A) / B-Field (+/-G)
- Right Arm D Momentum (GeV/c) / current (A) / B-Field (+/-G)
- Right Arm Q3 Momentum (GeV/c) / current (A) / B-Field (+/-G)
- Is Right VDC gas flow (top/bottom) on?
- Right VDC HV on (top/bottom)? (off normally)
Right Cerenkov HV on?Right Pion rejector HV on?- Right s0/s2m HV on?
- Main Detector HV
- GEM HV
Right SCIFI HV off (should be off during production runs, y/n)?S3 HV off (ch 6 of SCIFI HV GUI, should be off for production)?- Check online plots (y/n)? -RHRS
CODA
- Latest run type (Test, Physics,..)
- Is the auto replay script running (ask the analysis expert)?
Is the APEX run list (in a white binder) completed?AgreedPlease attach the left/right HV and Scalers Screenshots to the shift reportSuggest to modify to: Attach Hall A Tools screenshot, Septum Power supply screenshot, Septum pipe temperature screenshots, Collimator water temperature screen shots to shift report.- Check scalers Not sure we will keep the scalers during regular production running.
- Time of beginning of latest run (RHRS) Modify (RHRS) to Integrating DAQ
- Latest run number
Dead time (%)Agreed
Beamtime accounting
- Beamtime accounting table submitted? Generally this is done one hour before the end of shift so I am not sure how useful it is. Unless we want them to check this at the very end of the run; but that runs into the issue that they already took ~7h of data (possibility with problems).
In counting house
- Is the volume up on hacweb7? (both hardware and software)
- VESDA System OK? (VESDA is the smoke/fire detection and alarm system. Check the Hall A VESDA Console on the wall beside the door to the compter room
- Empty drip tray and place mug under spout on coffee maker
- Press the buttons on either side of the tray and pull toward you
- Place a mug under the spout while emptying the tray (and the previous mug) in the bathroom sink
- Replace the tray by sliding back into the machine
- Place a mug under the spout to help keep the tray from overflowing