Difference between revisions of "Full Shift Checklist"

From PREX Wiki
Jump to navigationJump to search
m
 
(7 intermediate revisions by 2 users not shown)
Line 1: Line 1:
 
<span style="color:red">In the process of editing and updating this page. Please contact Juliette Mammei <B>[mailto:crowder@jlab.org?Subject=PREXwiki crowder@jlab.org]</B> with questions or suggestions.</span>
 
<span style="color:red">In the process of editing and updating this page. Please contact Juliette Mammei <B>[mailto:crowder@jlab.org?Subject=PREXwiki crowder@jlab.org]</B> with questions or suggestions.</span>
 
<br><br>
 
<br><br>
[https://prex.jlab.org/wiki/index.php/Main_Page <B>PREX Main</B>]<< [[Information for Shift Takers]] << [[Shift Checklist]]
+
[[Main_Page|<B>PREX Main</B>]]<< [[Information for Shift Takers]] << [[Shift Checklist]]
  
 +
<br>
 +
 +
This is just where I have documented changes to the shift checklist!  Not really useful for anything else.
 +
 +
<br><br>
  
 
== Entering shift info ==
 
== Entering shift info ==
Line 8: Line 13:
 
* Shift leader
 
* Shift leader
 
* Target operator
 
* Target operator
* Analysis expert
+
* Analysis expert <span style="background-color:#F1C40F">Suggest remove</span>
 
* Shift (day, swing, or owl)
 
* Shift (day, swing, or owl)
** Enter the names of the shift workers (Shift leader, Target operator, Analysis expert)
+
** Enter the names of the shift workers (Shift leader, Target operator, Analysis expert) <span style="background-color:#F1C40F">We don't require an Analysis Expert so we should remove it from here</span>
 
** Indicate which shift the checklist is for (day, swing, or owl)
 
** Indicate which shift the checklist is for (day, swing, or owl)
  
 
== [[Beam and Hall checks]] ==
 
== [[Beam and Hall checks]] ==
  
* Is alarm handler running on hacweb7?
+
* Is alarm handler running on hacweb7? <span style="background-color:#F1C40F">Modify to: Is hall alarm handler running on hacweb7?</span>
* Beam Energy (GeV)
+
* <span style="background-color:#F1C40F">Add: Is experimental alarm handler running on hacweb7?</span>
* Beam current (µA)
+
* Beam Energy (GeV) <span style="background-color:#F1C40F">Suggest remove</span>
 +
* Beam current (µA)  
 
* Downstream raster (B) on? Yes/No
 
* Downstream raster (B) on? Yes/No
 
* Raster size (x:y mm, see log 3654466 )?
 
* Raster size (x:y mm, see log 3654466 )?
* Fast feedback on? Yes/No
+
* Fast feedback on? Yes/No  
 
* Beam Position Monitor X/Y (mm) A
 
* Beam Position Monitor X/Y (mm) A
 
* Beam Position Monitor X/Y (mm) E (BPM B in Hall A Tools)
 
* Beam Position Monitor X/Y (mm) E (BPM B in Hall A Tools)
* BCM temperature (K) (PV, PS, Thermocouple) If these differ by +/-.5 from (110.0,110.0,115.0) contact RC and halog
+
* <span style="background-color:#F1C40F">Add: Are Compton slow locks functioning?</span>
 +
* <span style="background-color:#F1C40F">Add: Are target slow locks functioning?</span>
 +
* <span style="background-color:#F1C40F">Add: Is the energy lock on?</span>
 +
* BCM temperature (K) (PV, PS, Thermocouple) If these differ by +/-.5 from (110.0,110.0,115.0) make halog entry and contact RC
 
* Arc energy NMR locked? ( (Goto ARC or the "Field Management Screen", and verify if the box locked is ON/OFF))
 
* Arc energy NMR locked? ( (Goto ARC or the "Field Management Screen", and verify if the box locked is ON/OFF))
 
* Current Target
 
* Current Target
Line 30: Line 39:
 
* CO2 pressure (psi)
 
* CO2 pressure (psi)
 
* Visual Hall Inspection OK?
 
* Visual Hall Inspection OK?
* <del> Truck ramp door closed ( use the camera to see the door from mirror)? </del>
+
* <del> Truck ramp door closed ( use the camera to see the door from mirror)? </del> * <span style="background-color:#F1C40F">Suggest remove</span>
 
* Septum current (A) and polarity?
 
* Septum current (A) and polarity?
* Upstream/downstream corrector currents (A) ?
+
* Upstream/downstream corrector currents (A) ? * <span style="background-color:#F1C40F">Suggest remove: we don't have correctors for our septum</span>
 +
 
 +
== [[Parity Checks]] ==
  
<span style="color:blue">
+
* <span style="color:blue"> IHWP setting (IN/OUT) </span>
* Parity Checks
+
** <span style="color:blue"> the button that is depressed is the setting </span> <span style="background-color:#F1C40F">I assume these are instructions (looks ok).</span>
** IHWP setting (IN/OUT)
+
** <span style="color:blue"> PGUN and parity controls </span> <span style="background-color:#F1C40F">Do you want something specific from here?</span>
*** the button that is depressed is the setting  
+
* <span style="color:blue"> RHWP setting (value like 1532) </span>
*** PGUN and parity controls
+
* <span style="color:blue"> Wien settings? </span>
** RHWP setting (value like 1532)
+
** <span style="color:blue"> Spin controls - jmenu search for spin </span> <span style="background-color:#F1C40F">I assume these are instructions (looks ok).</span>
** Wien settings?
+
** <span style="color:blue"> VWienAngle </span>
*** Spin controls - jmenu search for spin
+
** <span style="color:blue"> Phi_FG </span>
*** VWienAngle
+
** <span style="color:blue"> HWienAngle </span>
*** Phi_FG
+
** <span style="color:blue"> FLIP(-LEFT) (-RIGHT) </span>
*** HWienAngle
+
* <span style="color:blue">SAM HV</span>
*** FLIP(-LEFT) (-RIGHT)
+
* <span style="color:blue">Septum HV</span> <span style="background-color:#F1C40F">Add</span>
</span>
 
  
 
== [[Left Arm Checks]] ==
 
== [[Left Arm Checks]] ==
  
 
* Left Arm momentum (GeV)
 
* Left Arm momentum (GeV)
* Left Arm Q1, Q2, D, Q3 regulartors on (yes/no, ask experts)?
+
* Left Arm Q1, Q2, D, Q3 regulartors on (yes/no, ask experts)? <span style="background-color:#F1C40F">Suggest removing "on" since it hints that we need it on and I think we won't use them because they are set to momentum.</span>
 
* Left Arm cryo flow level OK? Yes/No He>60% (Ignore Nitrogen)
 
* Left Arm cryo flow level OK? Yes/No He>60% (Ignore Nitrogen)
 
* Left Arm NMR OK? Yes/No
 
* Left Arm NMR OK? Yes/No
Line 59: Line 69:
 
* Left Arm Q3 Momentum (GeV/c) / current (A) / B-Field (+/-G)
 
* Left Arm Q3 Momentum (GeV/c) / current (A) / B-Field (+/-G)
 
* Is Left VDC gas flow (top/bottom) on?
 
* Is Left VDC gas flow (top/bottom) on?
* Left VDC HV on (top/bottom)?
+
* Left VDC HV on (top/bottom)?<span style="color:blue"> (off normally)</span>
VDC thresholds (All 4 values should be 3.0 V, yes/no) ?
+
* VDC thresholds (All 4 values should be 3.0 V, yes/no) <span style="color:blue"> (off normally)</span>
Left Cerenkov HV on?
+
* <del> Left Cerenkov HV on? </del> <span style="background-color:#F1C40F">Agreed</span>
Left Pion rejector HV on?
+
* <del> Left Pion rejector HV on? </del> <span style="background-color:#F1C40F">Agreed</span>
Left s0/s2m HV on (s0 may be off for production, check with expert)?
+
* <span style="color:blue"> Main Detector HV </span>
Check online plots (y/n)? -LHRS
+
* <span style="color:blue"> GEM HV</span> <span style="background-color:#F1C40F">Add "normally off"</span>
 +
* Left s0/s2m HV on (s0 may be off for production, check with expert)?  
 +
* Check online plots (y/n)? -LHRS
  
 
== [[Right Arm Checks]] ==
 
== [[Right Arm Checks]] ==
 
+
<span style="background-color:#F1C40F">Similar to Left arm</span>
Right arm momentum (GeV)
+
* Right arm momentum (GeV)
Right Arm Q1, Q2,D,Q3 regulartor on? (yes/no)
+
* Right Arm Q1, Q2,D,Q3 regulartor on? (yes/no)
Right arm cryo flow level OK? Yes/No He>60% (Ignore Nitrogen)
+
* Right arm cryo flow level OK? Yes/No He>60% (Ignore Nitrogen)
Right Arm NMR OK? Yes/No
+
* Right Arm NMR OK? Yes/No
Right Arm Q1 Momentum (GeV/c) / current (A) / B-Field (+/-G)
+
* Right Arm Q1 Momentum (GeV/c) / current (A) / B-Field (+/-G)
Right Arm Q2 Momentum (GeV/c) / current (A) / B-Field (+/-G)
+
* Right Arm Q2 Momentum (GeV/c) / current (A) / B-Field (+/-G)
Right Arm D Momentum (GeV/c) / current (A) / B-Field (+/-G)
+
* Right Arm D Momentum (GeV/c) / current (A) / B-Field (+/-G)
Right Arm Q3 Momentum (GeV/c) / current (A) / B-Field (+/-G)
+
* Right Arm Q3 Momentum (GeV/c) / current (A) / B-Field (+/-G)
Is Right VDC gas flow (top/bottom) on?
+
* Is Right VDC gas flow (top/bottom) on?
Right VDC HV on (top/bottom)?
+
* Right VDC HV on (top/bottom)? <span style="color:blue"> (off normally)</span>
Right Cerenkov HV on?
+
* <del>  Right Cerenkov HV on? </del>
Right Pion rejector HV on?
+
* <del>  Right Pion rejector HV on? </del>
Right s0/s2m HV on?
+
Right s0/s2m HV on?
Right SCIFI HV off (should be off during production runs, y/n)?
+
* <span style="color:blue"> Main Detector HV </span>
S3 HV off (ch 6 of SCIFI HV GUI, should be off for production)?
+
* <span style="color:blue"> GEM HV</span>
Check online plots (y/n)? -RHRS
+
* <del>  Right SCIFI HV off (should be off during production runs, y/n)?</del>
 +
* <del> S3 HV off (ch 6 of SCIFI HV GUI, should be off for production)? </del>
 +
* Check online plots (y/n)? -RHRS
  
 
== [[CODA#Instructions for shift checklist|CODA]] ==
 
== [[CODA#Instructions for shift checklist|CODA]] ==
  
Latest run type (Test, Physics,..)
+
* Latest run type (Test, Physics,..)
Is the auto replay script running (ask the analysis expert)?
+
* Is the auto replay script running (ask the analysis expert)?
<del>Is the APEX run list (in a white binder) completed?</del>
+
* <del>Is the APEX run list (in a white binder) completed?</del>  <span style="background-color:#F1C40F">Agreed</span>
Please attach the left/right HV and Scalers Screenshots to the shift report
+
* <del>Please attach the left/right HV and Scalers Screenshots to the shift report</del>  <span style="background-color:#F1C40F">Suggest to modify to: Attach Hall A Tools screenshot, Septum Power supply screenshot, Septum pipe temperature screenshots, Collimator water temperature screen shots to shift report.</span>
Time of beginning of latest run (RHRS)
+
*  <span style="color:blue"> Check scalers</span> <span style="background-color:#F1C40F">Not sure we will keep the scalers during regular production running.</span>
Latest run number
+
* Time of beginning of latest run (RHRS) <span style="background-color:#F1C40F">Modify (RHRS) to Integrating DAQ</span>
<del>Dead time (%)</del>
+
* Latest run number
 +
* <del>Dead time (%)</del> <span style="background-color:#F1C40F">Agreed</span>
  
  
 
== [[BTA|Beamtime accounting]] ==
 
== [[BTA|Beamtime accounting]] ==
  
* Beamtime accounting table submitted?
+
* Beamtime accounting table submitted? <span style="background-color:#F1C40F">Generally this is done one hour before the end of shift so I am not sure how useful it is. Unless we want them to check this at the very end of the run; but that runs into the issue that they already took ~7h of data (possibility with problems).</span>
  
  

Latest revision as of 10:32, 11 July 2019

In the process of editing and updating this page. Please contact Juliette Mammei crowder@jlab.org with questions or suggestions.

PREX Main<< Information for Shift Takers << Shift Checklist


This is just where I have documented changes to the shift checklist! Not really useful for anything else.



Entering shift info

  • Shift leader
  • Target operator
  • Analysis expert Suggest remove
  • Shift (day, swing, or owl)
    • Enter the names of the shift workers (Shift leader, Target operator, Analysis expert) We don't require an Analysis Expert so we should remove it from here
    • Indicate which shift the checklist is for (day, swing, or owl)

Beam and Hall checks

  • Is alarm handler running on hacweb7? Modify to: Is hall alarm handler running on hacweb7?
  • Add: Is experimental alarm handler running on hacweb7?
  • Beam Energy (GeV) Suggest remove
  • Beam current (µA)
  • Downstream raster (B) on? Yes/No
  • Raster size (x:y mm, see log 3654466 )?
  • Fast feedback on? Yes/No
  • Beam Position Monitor X/Y (mm) A
  • Beam Position Monitor X/Y (mm) E (BPM B in Hall A Tools)
  • Add: Are Compton slow locks functioning?
  • Add: Are target slow locks functioning?
  • Add: Is the energy lock on?
  • BCM temperature (K) (PV, PS, Thermocouple) If these differ by +/-.5 from (110.0,110.0,115.0) make halog entry and contact RC
  • Arc energy NMR locked? ( (Goto ARC or the "Field Management Screen", and verify if the box locked is ON/OFF))
  • Current Target
  • Argon pressure (psi)
  • Ethane pressure (psi)
  • CO2 pressure (psi)
  • Visual Hall Inspection OK?
  • Truck ramp door closed ( use the camera to see the door from mirror)? * Suggest remove
  • Septum current (A) and polarity?
  • Upstream/downstream corrector currents (A) ? * Suggest remove: we don't have correctors for our septum

Parity Checks

  • IHWP setting (IN/OUT)
    • the button that is depressed is the setting I assume these are instructions (looks ok).
    • PGUN and parity controls Do you want something specific from here?
  • RHWP setting (value like 1532)
  • Wien settings?
    • Spin controls - jmenu search for spin I assume these are instructions (looks ok).
    • VWienAngle
    • Phi_FG
    • HWienAngle
    • FLIP(-LEFT) (-RIGHT)
  • SAM HV
  • Septum HV Add

Left Arm Checks

  • Left Arm momentum (GeV)
  • Left Arm Q1, Q2, D, Q3 regulartors on (yes/no, ask experts)? Suggest removing "on" since it hints that we need it on and I think we won't use them because they are set to momentum.
  • Left Arm cryo flow level OK? Yes/No He>60% (Ignore Nitrogen)
  • Left Arm NMR OK? Yes/No
  • Left Arm Q1 Momentum (GeV/c) / current (A) / B-Field (+/-G)
  • Left Arm Q2 Momentum (GeV/c) / current (A) / B-Field (+/-G)
  • Left Arm D Momentum (GeV/c) / current (A) / B-Field (+/-G)
  • Left Arm Q3 Momentum (GeV/c) / current (A) / B-Field (+/-G)
  • Is Left VDC gas flow (top/bottom) on?
  • Left VDC HV on (top/bottom)? (off normally)
  • VDC thresholds (All 4 values should be 3.0 V, yes/no) (off normally)
  • Left Cerenkov HV on? Agreed
  • Left Pion rejector HV on? Agreed
  • Main Detector HV
  • GEM HV Add "normally off"
  • Left s0/s2m HV on (s0 may be off for production, check with expert)?
  • Check online plots (y/n)? -LHRS

Right Arm Checks

Similar to Left arm
  • Right arm momentum (GeV)
  • Right Arm Q1, Q2,D,Q3 regulartor on? (yes/no)
  • Right arm cryo flow level OK? Yes/No He>60% (Ignore Nitrogen)
  • Right Arm NMR OK? Yes/No
  • Right Arm Q1 Momentum (GeV/c) / current (A) / B-Field (+/-G)
  • Right Arm Q2 Momentum (GeV/c) / current (A) / B-Field (+/-G)
  • Right Arm D Momentum (GeV/c) / current (A) / B-Field (+/-G)
  • Right Arm Q3 Momentum (GeV/c) / current (A) / B-Field (+/-G)
  • Is Right VDC gas flow (top/bottom) on?
  • Right VDC HV on (top/bottom)? (off normally)
  • Right Cerenkov HV on?
  • Right Pion rejector HV on?
  • Right s0/s2m HV on?
  • Main Detector HV
  • GEM HV
  • Right SCIFI HV off (should be off during production runs, y/n)?
  • S3 HV off (ch 6 of SCIFI HV GUI, should be off for production)?
  • Check online plots (y/n)? -RHRS

CODA

  • Latest run type (Test, Physics,..)
  • Is the auto replay script running (ask the analysis expert)?
  • Is the APEX run list (in a white binder) completed? Agreed
  • Please attach the left/right HV and Scalers Screenshots to the shift report Suggest to modify to: Attach Hall A Tools screenshot, Septum Power supply screenshot, Septum pipe temperature screenshots, Collimator water temperature screen shots to shift report.
  • Check scalers Not sure we will keep the scalers during regular production running.
  • Time of beginning of latest run (RHRS) Modify (RHRS) to Integrating DAQ
  • Latest run number
  • Dead time (%) Agreed


Beamtime accounting

  • Beamtime accounting table submitted? Generally this is done one hour before the end of shift so I am not sure how useful it is. Unless we want them to check this at the very end of the run; but that runs into the issue that they already took ~7h of data (possibility with problems).


In counting house

  • Is the volume up on hacweb7? (both hardware and software)
  • VESDA System OK? (VESDA is the smoke/fire detection and alarm system. Check the Hall A VESDA Console on the wall beside the door to the compter room
  • Empty drip tray and place mug under spout on coffee maker
    • Press the buttons on either side of the tray and pull toward you
    • Place a mug under the spout while emptying the tray (and the previous mug) in the bathroom sink
    • Replace the tray by sliding back into the machine
    • Place a mug under the spout to help keep the tray from overflowing