Difference between revisions of "Beam Recovery"
From PREX Wiki
Jump to navigationJump to searchLine 14: | Line 14: | ||
*<span style="color:blue">Check if the septum on !!</span> (It gets turned off for access, sometimes people forget.) | *<span style="color:blue">Check if the septum on !!</span> (It gets turned off for access, sometimes people forget.) | ||
− | *<span style="color: | + | *<span style="color:blue">Make sure we have Tune B.</span> (If someone has turned off HRS magnets they may not come back in right state.) |
# Empty target, establish correct beam position [[Beam and Hall checks#Beamline | Check beam position]] | # Empty target, establish correct beam position [[Beam and Hall checks#Beamline | Check beam position]] | ||
Line 42: | Line 42: | ||
#* See white board for which one we are using | #* See white board for which one we are using | ||
#* As I write this, we're using number 2 (middle). | #* As I write this, we're using number 2 (middle). | ||
− | #* IMPORTANT: Raster always on and 6x4 when Lead / Diamond target in beam !! | + | #* <span style="color:red">IMPORTANT:</span> Raster always on and 6x4 when Lead / Diamond target in beam !! |
− | #* Ask for the SAME attenuator and slit as above. | + | #* Ask for the <span style="color:red">SAME</span> attenuator and slit as above. |
#* Observe T5 = 13 +/- 3 kHz. This is fine. | #* Observe T5 = 13 +/- 3 kHz. This is fine. | ||
# Run spot_L again, this time with ps8=65535 and ps5=10 | # Run spot_L again, this time with ps8=65535 and ps5=10 | ||
Line 57: | Line 57: | ||
<span style="color:red">IMPORTANT:</span> Raster always on and 6x4 mm (observed on target) when Lead / Diamond target in beam !! | <span style="color:red">IMPORTANT:</span> Raster always on and 6x4 mm (observed on target) when Lead / Diamond target in beam !! | ||
− | # | + | # <span style="color:blue"> If you are unsure of raster status, check it !!</span> |
# Can be sure raster is ok if | # Can be sure raster is ok if | ||
#* You were just running and it was on. | #* You were just running and it was on. |
Revision as of 13:34, 18 June 2019
In the process of editing and updating this page. Please contact Juliette Mammei crowder@jlab.org with questions or suggestions.
PREX Main<< HOW TOs << Expert Tools
Procedure for Long Beam Down
- Check if the septum on !! (It gets turned off for access, sometimes people forget.)
- Make sure we have Tune B. (If someone has turned off HRS magnets they may not come back in right state.)
- Empty target, establish correct beam position Check beam position
- 5 uA empty target
- BPM4A (X,Y) = ( 0, 0) mm
- BPM4B (X,Y) = ( 0, +1) mm
- See white board for updates on these.
- Tolerances on these : +/- 0.3 mm
- Establish Raster
- It gets turned off for access, sometimes people forget.)
- Still at empty target.
- All scint HV off (normally they are).
- Need to use T8 pulser, so use ps8 = 2 on L-HRS.
- spot_L check of raster, see 6x4 mm2 on target
- Put in BeO target, for visual check of spot (if camera still works)
- 10 uA rastered beam on BeO.
- May need to request MCC for rapid beam-on / beam-off to see spot.
- "Rapid" can be done by turning on/off laser at polarized source.
- Establish 5 nA
- Still with BeO target
- Ask MCC for Laser Attenuator = 65 and Slit = 15. (This might need to change)
- These two knobs (atten and slit) can reduce current to nA range.
- Turn on L-HRS upper scintillator paddle HV which makes trigger T5.
- Card 2, chan 10, HV = -1400 V
- Should observe T5 = 2000 Hz +/- 1000. Adjust atten, slit if necessary.
- Put in the Lead / Diamond target
- See white board for which one we are using
- As I write this, we're using number 2 (middle).
- IMPORTANT: Raster always on and 6x4 when Lead / Diamond target in beam !!
- Ask for the SAME attenuator and slit as above.
- Observe T5 = 13 +/- 3 kHz. This is fine.
- Run spot_L again, this time with ps8=65535 and ps5=10
- Observe the raster current pattern, see if it's flat
- Flat means we're not hitting a frame !
- Gentle slope due in X is presumably form factor (don't worry)
- For reference, see halog 314132
- Turn off all scint HV.
- Ready for high current: Ramp up to 50 uA at about 10 uA per min.
Procedure for Short Beam Down or target movement
less than 2 hours of no beam, and no changes to beam
IMPORTANT: Raster always on and 6x4 mm (observed on target) when Lead / Diamond target in beam !!
- If you are unsure of raster status, check it !!
- Can be sure raster is ok if
- You were just running and it was on.
- Check the scope in middle room (familiar TV pattern of raster)
- Look at raster EPICS screen.
- To check raster:
- Go to empty target
- Ask for 5 uA
- Do a spot_L run with ps8=2 as explained above.
- Put in Pb/Diamond Target
- See white board for which one.
- As I write this, we are using number 2 (middle)
- Ask for 5 uA. Check beam positions.
- BPM4A (X,Y) = ( 0, 0) mm
- BPM4B (X,Y) = ( 0, +1) mm
- See white board for updates on these.
- Tolerances on these : +/- 0.3 mm
- If you didn't do spot_L in the first step, do one a quick one now.
- Want 6x4 mm on target.
- Ready for high current: Ramp up to 50 uA at about 10 uA per min.