===General Instructions for shift crew for parity running===
 +
*watch out for
 +
** ion chambers
 +
** collimator temps
 +
** detector voltages in pengui (usl 5.6 V usr 5.2 V at 70 uA)
 +
** BPM saturation
 +
** position locks for > 1 uA: BPMA (x=0.2; y=-0.5) BPME (x=0.2; y=-0.5)
 +
** raster : 12 by 7.2 in MCC units (width by height) raster synch/unsynced values in the white board outdated?
 +
* make sure
 +
** Charge feedback is on
 +
** FFB ON (see FFB GUI: FF ON, FF DAC ON, EnergyModeRF ON)
 +
** BeamMod ON after beam is established (BPM gains set and stable and FFB ON)
  
 
== Before your shift ==
 
== Before your shift ==

Revision as of 15:07, 7 August 2019

Quick Links
HOW TOs
Experts on call
Hall A Tools
Shift Checklist How To
CODA
Set HRS magnets
Online analysis How-To

In the process of editing and updating this page. Please contact Juliette Mammei crowder@jlab.org with questions or suggestions.

PREX Main


Important Note for Shift Workers

  • Post separate HALOG entry for status changes/events
  • Please fill out the Shift Checklist at the beginning of the shift
  • Access arrangement should be done through the Run Coordinator
  • Documentation of Online Plots
  • Documentation of all alarms
  • Determining tasks and allocating responsibilities is up to the Shift Leader and shift crew to decide amongst themselves at the beginning of a shift

General Instructions for shift crew for parity running

  • watch out for
    • ion chambers
    • collimator temps
    • detector voltages in pengui (usl 5.6 V usr 5.2 V at 70 uA)
    • BPM saturation
    • position locks for > 1 uA: BPMA (x=0.2; y=-0.5) BPME (x=0.2; y=-0.5)
    • raster : 12 by 7.2 in MCC units (width by height) raster synch/unsynced values in the white board outdated?
  • make sure
    • Charge feedback is on
    • FFB ON (see FFB GUI: FF ON, FF DAC ON, EnergyModeRF ON)
    • BeamMod ON after beam is established (BPM gains set and stable and FFB ON)

Before your shift

  • First!! Please read and sign the safety documentation in the counting house. A readable version can be found here!
  • Second!! Please sign up for more shifts


Shift Workers and Their Responsibilities

  • Shift Leader - Point of contact between RC/MCC and shift workers; takes data