=== Slug 13 === | === Slug 13 === | ||
− | * | + | * IHWP: Out |
+ | * Wien: Right | ||
+ | * Current: 70uA-50uA | ||
+ | ** Started from 70uA and went down to 50uA because the collimator temperature started increasing | ||
+ | * HRSs: Both Arms | ||
+ | ** PREX 1 thick Quartz (RHRS) and 5mm thin quartz (LHRS) | ||
=== Slug 14 === | === Slug 14 === |
Revision as of 10:45, 31 July 2019
Documentation |
HOW TOs for shift crew |
Expert Tools |
All Expert Contacts |
In the process of editing and updating this page. Please contact Juliette Mammei crowder@jlab.org with questions or suggestions.
PREX Main << Weekly Analysis Coordinator << Instructions
Weekly Analysis Coordinator Notes
Week 3 - Cameron
- Cameron Clarke:
Week 4 - Devi
- Devi Adhikari
Week 5 - Victoria
- Victoria Owen
Slug Summary Notes
Slug 0
Slug 1
Slug 2
Slug 3
- IHWP: Out
- Wien: Right
- Current: 50 uA
- BCM noise in BCM an us begins to be a problem
- HRSs: Both
- PREX 1 thick Quartz
- BCM: an_ds
- Analysis in adaqfs disks is still an_ds3 normalized at this time
Slug 4
- IHWP: Out
- Wien: Right
- Current: 50 uA
- HRSs: Both
- PREX 1 thick Quartz
- BCM: an_ds
- Analysis in adaqfs disks is an_ds3 normalized at this time
Slug 5
- IHWP: Out
- Wien: Right
- Current: 70 uA
- HRSs: Both
- PREX 1 thick Quartz
- BCM: an_ds
- Analysis in adaqfs disks is an_ds3 normalized at this time
Slug 6
- IHWP: Out
- Wien: Right
- Current: 50 uA
- HRSs: Both
- PREX 1 thick Quartz
- BCM: an_ds
- Analysis in adaqfs disks is an_ds3 normalized at this time
Slug 7
- IHWP: Out
- Wien: Right
- Current: 50 uA
- HRSs: Both
- PREX 1 thick Quartz
- BCM: an_ds
- Analysis in adaqfs disks is an_ds3 normalized at this time
Slug 8
- IHWP: In
- Wien: Right
- Current: 50 uA
- PQB commences
- HRSs: Left arm only
- PREX 1 thick Quartz
- BCM: an_ds
- This is when we switched to an_ds from an_ds3 (in the maps being used by adaqfs at this time)
Slug 9
- IHWP: Out
- Wien: Right
- Current: 50 uA
- HRSs: Left arm only
- PREX 1 thick Quartz
- BCM: an_ds
Slug 10
- IHWP: In
- Wien: Right
- Current: 50 uA
- HRSs: Left arm only
- PREX 1 thick Quartz
- BCM: an_ds
- This was a particularly noisy beam motion slug. FFB was off most of the time
Slug 11
- IHWP: Out
- Wien: Right
- Current: 50 uA
- HRSs: Left arm only
- PREX 1 thick Quartz
- BCM: an_ds
- FFB has now been turned on perpetually, and beam motion is stable, but the BPMs are noisier
Slug 12
- IHWP: IN
- Wien: Right
- Current: 70 uA
- HRSs: Both Arms
- PREX 1 thick Quartz in RHRS
- RHRS Returns to usability
- New PREX II Quartz in Left Arm Only at this time
- analog BCMs started being noisy
- Tried bpm4ec and returned back to bpm4e for regression
- use bpm11X instead of bpm12X
Slug 13
- IHWP: Out
- Wien: Right
- Current: 70uA-50uA
- Started from 70uA and went down to 50uA because the collimator temperature started increasing
- HRSs: Both Arms
- PREX 1 thick Quartz (RHRS) and 5mm thin quartz (LHRS)
Slug 14
Slug 15
Slug 16
Slug 17
Slug 18
Slug 19
Slug 20
Slug 21
- New PREX II Quartz in Right Arm also now