WAC Notes August 6 2019

From PREX Wiki
Jump to navigationJump to search
Documentation
HOW TOs for shift crew
Expert Tools
All Expert Contacts



PREX Main << Weekly Analysis Coordinator << WAC Notes << Instructions

WAC Notes August 5 2019 << >> WAC Notes August 7 2019

August 6 2019

Daily Meeting BlueJeans

Production Run List

  • Slug 29, Wein_Left, IHWP_IN (continued from Aug.4 runs 3841-)
    • run 3857-3862 : good production running
  • Slug 29: Good Charge: 1.85C, Total Charge: 2.32C
  • Slug 30, Wien_Left, IHWP_OUT
    • run 3863-3866: good production running
    • run 3874-3875: good running 120Hz
    • run 3877-3881: good running 240Hz

Non-Production Runs and Bad Runs

Pedestal/Calibrations Updates

  • Slug30
    • run 3867: PITA scan
    • run 3868: 0uA 240Hz Test

Issues

  • asym_bcm_dg_us_bcm_an_ds_agg_avg and asym_bcm_dg_ds_bcm_an_ds_agg_avg

have the same values in their plots (and therefore fits) as well as their double differences

  • asym_bcm_dg_us_bcm_an_ds_agg_dd and asym_bcm_dg_ds_bcm_an_ds_agg_dd
      • this has been fixed***

Other Status Updates

  • Begin 240 Hz on run 3876