Difference between revisions of "Full Shift Checklist"
From PREX Wiki
Jump to navigationJump to searchLine 34: | Line 34: | ||
* Upstream/downstream corrector currents (A) ? | * Upstream/downstream corrector currents (A) ? | ||
− | <span style="color:blue"> | + | |
− | + | * <span style="color:blue"> Parity Checks </span> | |
− | ** IHWP setting (IN/OUT) | + | ** <span style="color:blue"> IHWP setting (IN/OUT) </span> |
− | *** the button that is depressed is the setting | + | *** <span style="color:blue"> the button that is depressed is the setting </span> |
− | *** PGUN and parity controls | + | *** <span style="color:blue"> PGUN and parity controls </span> |
− | ** RHWP setting (value like 1532) | + | ** <span style="color:blue"> RHWP setting (value like 1532) </span> |
− | ** Wien settings? | + | ** <span style="color:blue"> Wien settings? </span> |
− | *** Spin controls - jmenu search for spin | + | *** <span style="color:blue"> Spin controls - jmenu search for spin </span> |
− | *** VWienAngle | + | *** <span style="color:blue"> VWienAngle </span> |
− | *** Phi_FG | + | *** <span style="color:blue"> Phi_FG </span> |
− | *** HWienAngle | + | *** <span style="color:blue"> HWienAngle </span> |
− | *** FLIP(-LEFT) (-RIGHT) | + | *** <span style="color:blue"> FLIP(-LEFT) (-RIGHT) </span> |
− | </span> | + | |
== [[Left Arm Checks]] == | == [[Left Arm Checks]] == |
Revision as of 12:25, 12 June 2019
In the process of editing and updating this page. Please contact Juliette Mammei crowder@jlab.org with questions or suggestions.
PREX Main<< Information for Shift Takers << Shift Checklist
Entering shift info
- Shift leader
- Target operator
- Analysis expert
- Shift (day, swing, or owl)
- Enter the names of the shift workers (Shift leader, Target operator, Analysis expert)
- Indicate which shift the checklist is for (day, swing, or owl)
Beam and Hall checks
- Is alarm handler running on hacweb7?
- Beam Energy (GeV)
- Beam current (µA)
- Downstream raster (B) on? Yes/No
- Raster size (x:y mm, see log 3654466 )?
- Fast feedback on? Yes/No
- Beam Position Monitor X/Y (mm) A
- Beam Position Monitor X/Y (mm) E (BPM B in Hall A Tools)
- BCM temperature (K) (PV, PS, Thermocouple) If these differ by +/-.5 from (110.0,110.0,115.0) contact RC and halog
- Arc energy NMR locked? ( (Goto ARC or the "Field Management Screen", and verify if the box locked is ON/OFF))
- Current Target
- Argon pressure (psi)
- Ethane pressure (psi)
- CO2 pressure (psi)
- Visual Hall Inspection OK?
Truck ramp door closed ( use the camera to see the door from mirror)?- Septum current (A) and polarity?
- Upstream/downstream corrector currents (A) ?
- Parity Checks
- IHWP setting (IN/OUT)
- the button that is depressed is the setting
- PGUN and parity controls
- RHWP setting (value like 1532)
- Wien settings?
- Spin controls - jmenu search for spin
- VWienAngle
- Phi_FG
- HWienAngle
- FLIP(-LEFT) (-RIGHT)
- IHWP setting (IN/OUT)
Left Arm Checks
- Left Arm momentum (GeV)
- Left Arm Q1, Q2, D, Q3 regulartors on (yes/no, ask experts)?
- Left Arm cryo flow level OK? Yes/No He>60% (Ignore Nitrogen)
- Left Arm NMR OK? Yes/No
- Left Arm Q1 Momentum (GeV/c) / current (A) / B-Field (+/-G)
- Left Arm Q2 Momentum (GeV/c) / current (A) / B-Field (+/-G)
- Left Arm D Momentum (GeV/c) / current (A) / B-Field (+/-G)
- Left Arm Q3 Momentum (GeV/c) / current (A) / B-Field (+/-G)
- Is Left VDC gas flow (top/bottom) on?
- Left VDC HV on (top/bottom)?
- VDC thresholds (All 4 values should be 3.0 V, yes/no) ?
Left Cerenkov HV on?Left Pion rejector HV on?Left s0/s2m HV on (s0 may be off for production, check with expert)?- Check online plots (y/n)? -LHRS
Right Arm Checks
- Right arm momentum (GeV)
- Right Arm Q1, Q2,D,Q3 regulartor on? (yes/no)
- Right arm cryo flow level OK? Yes/No He>60% (Ignore Nitrogen)
- Right Arm NMR OK? Yes/No
- Right Arm Q1 Momentum (GeV/c) / current (A) / B-Field (+/-G)
- Right Arm Q2 Momentum (GeV/c) / current (A) / B-Field (+/-G)
- Right Arm D Momentum (GeV/c) / current (A) / B-Field (+/-G)
- Right Arm Q3 Momentum (GeV/c) / current (A) / B-Field (+/-G)
- Is Right VDC gas flow (top/bottom) on?
- Right VDC HV on (top/bottom)?
Right Cerenkov HV on?Right Pion rejector HV on?Right s0/s2m HV on?Right SCIFI HV off (should be off during production runs, y/n)?S3 HV off (ch 6 of SCIFI HV GUI, should be off for production)?- Check online plots (y/n)? -RHRS
CODA
- Latest run type (Test, Physics,..)
- Is the auto replay script running (ask the analysis expert)?
Is the APEX run list (in a white binder) completed?Please attach the left/right HV and Scalers Screenshots to the shift report- Time of beginning of latest run (RHRS)
- Latest run number
Dead time (%)
Beamtime accounting
- Beamtime accounting table submitted?
In counting house
- Is the volume up on hacweb7? (both hardware and software)
- VESDA System OK? (VESDA is the smoke/fire detection and alarm system. Check the Hall A VESDA Console on the wall beside the door to the compter room
- Empty drip tray and place mug under spout on coffee maker
- Press the buttons on either side of the tray and pull toward you
- Place a mug under the spout while emptying the tray (and the previous mug) in the bathroom sink
- Replace the tray by sliding back into the machine
- Place a mug under the spout to help keep the tray from overflowing