Difference between revisions of "WAC Notes August 6 2019"
From PREX Wiki
Jump to navigationJump to searchLine 26: | Line 26: | ||
*Slug 29: Good Charge: 1.85C, Total Charge: 2.32C | *Slug 29: Good Charge: 1.85C, Total Charge: 2.32C | ||
− | *Slug 30, | + | *Slug 30, Wien_Left, IHWP_OUT |
** run 3863-3866: good production running | ** run 3863-3866: good production running | ||
** run 3874-3875: good running 120Hz | ** run 3874-3875: good running 120Hz |
Latest revision as of 18:01, 10 August 2019
Documentation |
HOW TOs for shift crew |
Expert Tools |
All Expert Contacts |
PREX Main << Weekly Analysis Coordinator << WAC Notes << Instructions
WAC Notes August 5 2019 << >> WAC Notes August 7 2019
August 6 2019
Daily Meeting BlueJeans
Production Run List
- Slug 29, Wein_Left, IHWP_IN (continued from Aug.4 runs 3841-)
- run 3857-3862 : good production running
- Slug 29: Good Charge: 1.85C, Total Charge: 2.32C
- Slug 30, Wien_Left, IHWP_OUT
- run 3863-3866: good production running
- run 3874-3875: good running 120Hz
- run 3877-3881: good running 240Hz
Non-Production Runs and Bad Runs
Pedestal/Calibrations Updates
- Slug30
- run 3867: PITA scan
- run 3868: 0uA 240Hz Test
Issues
- asym_bcm_dg_us_bcm_an_ds_agg_avg and asym_bcm_dg_ds_bcm_an_ds_agg_avg
have the same values in their plots (and therefore fits) as well as their double differences
- asym_bcm_dg_us_bcm_an_ds_agg_dd and asym_bcm_dg_ds_bcm_an_ds_agg_dd
- this has been fixed***
Other Status Updates
- Begin 240 Hz on run 3876