CREX Detailed High current plan

From PREX Wiki
Jump to navigationJump to search

PREX version, CREX Calibration Plan, CREX Production Plan

Beamline instrumentation calibration - All copied from PREX, updated to CREX numbers

  1. Check detector alignment and pulse height (Done)
    • 1uA Hall A Target BPM lock (with Cavities if required, probably not)
    • 0.2% Carbon
    • 20 nA, cavity locks on and cavities in low current mode
    • VDC on.
    • Check rates, verify pulse height spectra and alignment
    • Modify DAQ to include GEMS. 10 minute run with GEMS.
  2. C-Hole target, verify spot (Done)
    • 20 nA, spot ++ verify raster size
    • harp scan 4e, verify intrinsic size at target
  3. High current - no target (Skip it tonight)
    • verify compton rates
  4. Ramp to SAM Shutter test
    • Insert Lead Target.
    • Raster 10x10.
    • 20 nA. (Atten 107, slit 15)
    • Cav locks on
    • spot++ verify not seeing edges
    • Set raster ?x? (to get (x.y) = 4x6 real)
  5. Go up in current 1uA (5min)
    • All HV off in HRS hut
    • Target lock (0.6mm, 0.4mm) -> (-0.3, -0.5) is collimator hole center for CREX
    • Collimator water temp
    • Beamline temperatures
    • Ion chamber (stability)
    • SAM yields
    • BCM and BPM yields, widths.
  6. Aaccess to remove SAM shutters, detector to integrate mode.
  7. Ramp to High current test.
    • Cavity bpm back to high current mode
    • All HV off in HRS hut, except quartz
    • Target lock (0.6mm, 0.4mm)
  8. 20uA (review) (10min)
    • Target lock, FFB (monitor bpm Saturation)
    • Collimator water temp
    • Beamline temperatures
    • Ion chamber (stability)
    • SAM and DET yields and widths
    • BCM and BPM yields, widths.
  9. 100uA (review) (10min)
    • Target lock, FFB (monitor bpm SAT)
    • Collimator water temp
    • beamline temperatures
    • Ion chamber (stability)
    • SAM and DET yields and widths
    • BCM and BPM yields, widths.
  10. 150A(1hr)
    • Target lock, FFB (monitor bpm SAT)
    • Aq feedback
    • Collimator water temp
    • beamline temperatures
    • Ion chamber (stability)
    • SAM and DET yields and widths
    • BCM and BPM yields, widths.
  11. Calibration scan, see Calibration Plan
    • FFB ON
    • To 150 uA
    • SAMs HVs set
    • DETs HVs set
    • PITA scan at end to check det linearities later
  12. BMW
    • Tune beam, slow lock on (ad FFB on?), exercise BMW, check no ion chamber trips, check pauses locks and FFB
    • Low current 2-3uA, exercise BMW, check BPM signals, check no ion chamber issues
    • Target in, low current 2-3uA,exercise BMW, check BPM signals, check no ion chamber issues
    • "Ready for high current"