Parity feedback and Analysis Minder
From PREX Wiki
Jump to navigationJump to searchHow to Run Feedback - with Analysis Minder GUI
- From the CODA session's "startcoda" command, a grey "PREX Analyzer Control Tool" should appear
- If not then type "restartMinder" from the command line to get a fresh copy
- From this gui you can find the Feedback anaylzer control buttons in the top left portion
- Start a new feedback instance with the "Launch Feedback RunForever" button
- Also open the feedback log to visually watch the feedback engine successfully connect to our data stream
- Once "good" beam is available the feedback engine should make corrections every so often for Halls A and C
- There are also EPICS strip charts saved in the CREX LivePlot folder that you can monitor the success of the feedback convergence with
How to Run Feedback - manually, with no Analysis Minder GUI
- Make sure Coda is running
- You need to be logged in apar account on adqa1:
ssh apar@adaq1
- Do gojapan
- Go to directory:
cd /adaqfs/home/apar/PREX/japan_feedback/
- Run feedback code:
./feedback_ana
- Also,make sure to change the event cut parameter file for appropriate current cuts(If the current is 50ua do 45uA current cut), To change that file
- 1.Go to directory:
cd /adaqfs/home/apar/PREX/japan_feedback/Parity/prminput
- 1.Go to directory:
- 2.Change, bcm_an_ds3 cut
prexCH_beamline_eventcuts.9999990.map
- 2.Change, bcm_an_ds3 cut
- Feedback will automatically run
- In order to quit Feedback
control+c
to crash out of the feedback