Difference between revisions of "Beam and Hall checks"

From PREX Wiki
Jump to navigationJump to search
Line 4: Line 4:
  
 
[[File:Snapshot_1_1762.png|thumb|600px|right|Figure 1 - Alarm handler window when there is a red alarm.  If nothing is alarming, it would be grey.]]
 
[[File:Snapshot_1_1762.png|thumb|600px|right|Figure 1 - Alarm handler window when there is a red alarm.  If nothing is alarming, it would be grey.]]
[[File:Halla_tools.png|thumb|600px|right|Figure 2 - Hall A General Tools screen (beam is off), where you can find most of the information needed here.]]
+
[[File:Halla_beamline_section.png|thumb|600px|right|Figure - ]]
 +
[[File:Hallatools_HRS.png|thumb|600px|right|Figure  - ]]
 +
[[File:Halltools_gas.png|thumb|600px|right|Figure  - ]]
 +
[[File:Halltools_vdc.png|thumb|600px|right|Figure  - ]]
 +
[[File:Halltools_vdc2.png|thumb|600px|right|Figure  - ]]
 +
[[File:Halltools_other.png|thumb|600px|right|Figure  - ]]
 +
 
 +
 
 
<br><br>
 
<br><br>
  

Revision as of 17:40, 12 June 2019

In the process of editing and updating this page. Please contact Juliette Mammei crowder@jlab.org with questions or suggestions.

PREX Main<< Information for Shift Takers << Shift Leader << Shift Checklist

Figure 1 - Alarm handler window when there is a red alarm. If nothing is alarming, it would be grey.
Figure -
Figure -
Figure -
Figure -
Figure -
Figure -




Alarm Handler

  • Is alarm handler running on hacweb7?
    • On hacweb 7, you should see a window in the upper right corner of the screen
      • Look first in the "Alarm Handler" desktop to see if it is there
      • Check all the windows if not
    • If not open, see Alarm Handler
  • Is the volume up on hacweb7? (both hardware and software)


Hall A Tools and related menu screens

  • Beam Energy (GeV)
    • Look at the lower left green "beamline" box
    • The beam energy can be found in the upper right of this box
  • Beam current (µA)
    • Look on the
  • Downstream raster (B) on? Yes/No (upstream raster is not in use)
    • picture of scope when raster is off, and when raster is on
  • Raster size (x:y mm, see log 3654466 )?
  • Fast feedback on? Yes/No
  • Beam Position Monitor X/Y (mm) A
  • Beam Position Monitor X/Y (mm) E (BPM B in Hall A Tools)
  • BCM temperature (K) (PV, PS, Thermocouple) If these differ by +/-.5 from (110.0,110.0,115.0) (Fahrenheit) contact RC and halog
    • These temperature readbacks are located in the middle DAQ room, in rack CH0B06 (far left) at the very top
    • It is important that these temperatures stay stable within 0.5 Fahrenheit or else the BCM current readout will become uncalibrated
  • Arc energy NMR locked? ( (Goto ARC or the "Field Management Screen", and verify if the box locked is ON/OFF))
  • VESDA System OK? (VESDA is the smoke/fire detection and alarm system. Check the Hall A VESDA Console on the wall behind the door
  • Current Target
  • Argon pressure (psi)
  • Ethane pressure (psi)
  • CO2 pressure (psi)
  • Visual Hall Inspection OK?
  • Septum current (A) and polarity?
  • Upstream/downstream corrector currents (A) ?
  • Check the scalers