* Beam Position Monitor (BPM) X/Y (mm) E (Called BPM B in Hall A Tools)
 
* Beam Position Monitor (BPM) X/Y (mm) E (Called BPM B in Hall A Tools)
 
<br>
 
<br>
* Downstream raster (B) on? Yes/No (upstream raster is not in use)
+
* Downstream raster (labelled B or 2, US raster is not in use) on?  
 +
** Check the Oscilloscope in Counting House Middle Room: Yes/No
 
** when raster is off, looks like Figure 3
 
** when raster is off, looks like Figure 3
 
** when raster is on, something like halog [https://logbooks.jlab.org/entry/3654466 3654466]
 
** when raster is on, something like halog [https://logbooks.jlab.org/entry/3654466 3654466]
* BCM temperature (K) (PV, PS, Thermocouple)
 
** If these differ by +/-.5 from (110.0, 110.0, 115.0) (Fahrenheit) <b>contact RC and halog</b>
 
** These temperature readbacks are located in the middle DAQ room, in rack CH0B06 (far left) at the very top  (see Figure 4)
 
** It is important that these temperatures stay stable within 0.5 Fahrenheit or else the BCM current readout will become uncalibrated
 
 
* Raster size (x:y mm, see log [https://logbooks.jlab.org/entry/3654466 3654466])?
 
* Raster size (x:y mm, see log [https://logbooks.jlab.org/entry/3654466 3654466])?
 
* Fast feedback (FFB) on? Yes/No
 
* Fast feedback (FFB) on? Yes/No
Line 52: Line 49:
 
** FFB should be <b>ON</b> during normal production running!
 
** FFB should be <b>ON</b> during normal production running!
 
** However, FFB will be paused during beam modulation
 
** However, FFB will be paused during beam modulation
* Arc energy NMR locked?  
+
* BCM temperature (K) (PV, PS, Thermocouple)
** Go to ARC or the "Field Management Screen"
+
** If these differ by +/-.5 from (110.0, 110.0, 115.0) (Fahrenheit) <b>contact RC and halog</b>
 +
** These temperature readbacks are located in the middle DAQ room, in rack CH0B06 (far left) at the very top  (see Figure 4)
 +
** It is important that these temperatures stay stable within 0.5 Fahrenheit or else the BCM current readout will become uncalibrated
 +
* Accelerator Arc Beam Energy NMR locked?
 +
** Go to "Energy Lock GUI" from JMenu -> Applications section -> "Energy Locks"
 
** Verify if the box locked is ON/OFF
 
** Verify if the box locked is ON/OFF
  

Revision as of 19:45, 23 June 2019

In the process of editing and updating this page. Please contact Juliette Mammei crowder@jlab.org with questions or suggestions.

PREX Main<< Information for Shift Takers << Shift Leader << Shift Checklist

Figure 1 - Alarm handler window when there is a red alarm. If nothing is alarming, it would be grey.
Figure 2 - The beeamline section in the Hall A Tools window.
Figure 3 - A picture of the scope when the raster is off. This would be BAD if beam were on!
Figure 4 - Picture of the BCM temperature readout in the computer room.
Figure 5 - Snapshot of the Fast Feedback Controls when the FFB is OFF.
Figure 6 - The gas section in the Hall A Tools window.
Figure 7 - Camera and alignment info in the Hall A Tools window.
Figure 8 - The VESDA panel in the counting house.
Figure 9 - Where you can find the camera display and the controls in the counting house.
Figure 10 - The camera controls.




Alarm Handler

  • Is alarm handler running on hacweb7?
    • On hacweb 7, you should see a window in the upper right corner of the screen
      • Look first in the "Alarm Handler" desktop to see if it is there
      • Check all the windows if not
    • If not open, see Alarm Handler
  • Is the volume up on hacweb7? (both hardware and software)


Hall A Tools and related menu screens

Beamline

  • Beam Energy (MeV) (see Figure 2)
  • Beam Current (µA)
  • Beam Position Monitor (BPM) X/Y (mm) A
  • Beam Position Monitor (BPM) X/Y (mm) E (Called BPM B in Hall A Tools)


  • Downstream raster (labelled B or 2, US raster is not in use) on?
    • Check the Oscilloscope in Counting House Middle Room: Yes/No
    • when raster is off, looks like Figure 3
    • when raster is on, something like halog 3654466
  • Raster size (x:y mm, see log 3654466)?
  • Fast feedback (FFB) on? Yes/No
    • To check whether the FFB is on or off
      • in a terminal window, type JMenu
      • search for "fast"
      • Choose "Fast Feedback Control" (see Figure 5, which is for FFB OFF)
      • The status is indicated by the button that is depressed (OFF and RUN in the figure)
    • FFB should be ON during normal production running!
    • However, FFB will be paused during beam modulation
  • BCM temperature (K) (PV, PS, Thermocouple)
    • If these differ by +/-.5 from (110.0, 110.0, 115.0) (Fahrenheit) contact RC and halog
    • These temperature readbacks are located in the middle DAQ room, in rack CH0B06 (far left) at the very top (see Figure 4)
    • It is important that these temperatures stay stable within 0.5 Fahrenheit or else the BCM current readout will become uncalibrated
  • Accelerator Arc Beam Energy NMR locked?
    • Go to "Energy Lock GUI" from JMenu -> Applications section -> "Energy Locks"
    • Verify if the box locked is ON/OFF

Gasses

  • Pressures (see Figure 6)
    • Argon pressure (psi)
    • Ethane pressure (psi)
    • CO2 pressure (psi)
  • VESDA System OK? (see Figure 8)
    • VESDA is the smoke/fire detection and alarm system
    • Check the Hall A VESDA Console on the wall behind the door


Hall/Counting House

  • Visual Hall Inspection OK? (see Figure 9)
    • Make sure to move the camera around and zoom in (See Figure 10)
    • when complete, zoom all the way back out
  • Current Target (snapshot)
  • Septum current (A) and polarity?
  • Upstream/downstream corrector currents (A) ?




Next in checklist >> Parity Checks