Difference between revisions of "DAQ Layouts"
(Created page with "Further information is available in DAQ Documentation Portal and DAQ Testing Portal Maps and layout schematics of the various DAQ systems r...") |
|||
(14 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
Further information is available in [[DAQ_Doc_Portal|DAQ Documentation Portal]] and [[DAQ_Testing|DAQ Testing Portal]] | Further information is available in [[DAQ_Doc_Portal|DAQ Documentation Portal]] and [[DAQ_Testing|DAQ Testing Portal]] | ||
− | Maps and layout schematics of the various DAQ systems relevant for running Hall A Parity experiments | + | Maps and layout schematics of the various DAQ systems relevant for running Hall A Parity experiments. |
+ | |||
See also - [[DAQ Commissioning Notes]], [[DAQ Testing]] | See also - [[DAQ Commissioning Notes]], [[DAQ Testing]] | ||
== Hall A Counting House Parity DAQ == | == Hall A Counting House Parity DAQ == | ||
+ | === UPDATE 7/5/2019 === | ||
+ | I changed the timing a bit, put back to 1024 after we had been in beam synch 1021 num_samples. Made sure the timebrd integration gate matches: https://logbooks.jlab.org/entry/3698934. The DocDB timing diagram has been updated with this timing information now too, and [[:media:Timing_Diagram_07052019.pdf|here is the wiki .pdf copy]]. | ||
+ | |||
+ | === 6/12/2019 === | ||
+ | [[:media:Parity-DAQ-6-12-2019.pdf|Timing diagrams and P2P maps of CH and RHS crates]], [[:media:Channel-Map.pdf|Channel Maps]], [[:media:TimingDiagrams.pdf|Timing Diagrams]] | ||
+ | |||
+ | === 4/4/2019 === | ||
+ | A point to point map from April 4th 2019 is [[:media:DAQ-Documentation-4-4-2019.pdf|here]]. | ||
+ | === 2/20/2019 === | ||
+ | The counting house Beamline Monitoring DAQ layout is (February 20th) documented in [https://ace.phys.virginia.edu:80/HAPPEX/3603 HAPLOG 3603] | ||
== Injector DAQ == | == Injector DAQ == | ||
+ | === Injector Timing Diagram === | ||
+ | ==== Current ==== | ||
+ | See [[DAQ_Testing/20181106|DAQ Testing 11-6-2018]] | ||
+ | |||
+ | ==== Old ==== | ||
+ | [[image:Injector_helicity.png|Injector_helicity.png]] | ||
+ | * August 10th 2018 - [[media:Injector_helicity.png|Injector_helicity.png]] - see [[DAQ Meeting/20180810|DAQ Meeting 8-10-2018]] | ||
+ | * August 1st 2018 - [[media:Injector_helicity_old.png|Injector_helicity_old.png]] | ||
== L/RHRS DAQ == | == L/RHRS DAQ == |
Latest revision as of 13:41, 8 July 2019
Further information is available in DAQ Documentation Portal and DAQ Testing Portal
Maps and layout schematics of the various DAQ systems relevant for running Hall A Parity experiments.
See also - DAQ Commissioning Notes, DAQ Testing
Hall A Counting House Parity DAQ
UPDATE 7/5/2019
I changed the timing a bit, put back to 1024 after we had been in beam synch 1021 num_samples. Made sure the timebrd integration gate matches: https://logbooks.jlab.org/entry/3698934. The DocDB timing diagram has been updated with this timing information now too, and here is the wiki .pdf copy.
6/12/2019
Timing diagrams and P2P maps of CH and RHS crates, Channel Maps, Timing Diagrams
4/4/2019
A point to point map from April 4th 2019 is here.
2/20/2019
The counting house Beamline Monitoring DAQ layout is (February 20th) documented in HAPLOG 3603
Injector DAQ
Injector Timing Diagram
Current
Old
- August 10th 2018 - Injector_helicity.png - see DAQ Meeting 8-10-2018
- August 1st 2018 - Injector_helicity_old.png