Difference between revisions of "HOW TOs"
From PREX Wiki
Jump to navigationJump to searchm (→Polarization) |
|||
(13 intermediate revisions by 6 users not shown) | |||
Line 12: | Line 12: | ||
* Analyze ("fast prompt") each run and review the prompt plots. | * Analyze ("fast prompt") each run and review the prompt plots. | ||
* (new, Aug 19) Run the Compton DAQ | * (new, Aug 19) Run the Compton DAQ | ||
+ | * (new, Feb 28) Run the Compton Counting Mode DAQ | ||
==Taking Data == | ==Taking Data == | ||
Line 19: | Line 20: | ||
* [[CODA#Starting a run| Starting a Run]] | * [[CODA#Starting a run| Starting a Run]] | ||
* [[Compton DAQ HOWTO#Compton DAQ CODA| Starting the Compton CODA]] | * [[Compton DAQ HOWTO#Compton DAQ CODA| Starting the Compton CODA]] | ||
− | * [[Compton DAQ HOWTO#Starting and Stopping a Compton Run| Starting a Compton Run]] | + | * [[Compton DAQ HOWTO#Starting and Stopping a Compton Run| Starting, Ending & Analyzing a Compton Run]] |
+ | * [[Compton Counting Mode DAQ| Starting the Compton Counting Mode DAQ]] | ||
* [[CODA#Starting a run| Taking a run]] | * [[CODA#Starting a run| Taking a run]] | ||
* [[Online analysis|Online analysis How-To]] | * [[Online analysis|Online analysis How-To]] | ||
Line 27: | Line 29: | ||
* [[GoToCavityLock| How to go to cavity lock with low current]]<b><span style ="color:red"> - this is NOT required for CREX </span></b> | * [[GoToCavityLock| How to go to cavity lock with low current]]<b><span style ="color:red"> - this is NOT required for CREX </span></b> | ||
* [[Doing a calibration run]] | * [[Doing a calibration run]] | ||
− | * [[Taking MAIN detector Counting Run]] | + | * [[Taking MAIN detector Counting Run]] (Alignment Check) |
== PREX Collimator (Septum Temperatures) == | == PREX Collimator (Septum Temperatures) == | ||
Line 55: | Line 57: | ||
== Fast Feedback == | == Fast Feedback == | ||
− | * | + | * If FFB broken badly, execute Plan B. [[FFB_troubleshooting]] |
== Reporting == | == Reporting == | ||
Line 84: | Line 86: | ||
* [[Strip chart]] | * [[Strip chart]] | ||
* [[Beam and Hall checks#Beamline | Check the raster]] | * [[Beam and Hall checks#Beamline | Check the raster]] | ||
+ | * [[Compton DAQ HOWTO#Compton Monitoring | Monitoring the Compton Rates]] | ||
+ | |||
== Beam Modulation== | == Beam Modulation== | ||
*[[How to run]] | *[[How to run]] | ||
Line 98: | Line 102: | ||
* Magnets | * Magnets | ||
* [[Power_outage_recovery|Recovering from Power Outage]] | * [[Power_outage_recovery|Recovering from Power Outage]] | ||
− | * [[Beam Recovery|Coming back from no beam]] | + | * '''OLD''' [[Beam Recovery|Coming back from no beam]] |
+ | * '''NEW''' [[Establishing High Current on a Calcium Target]] | ||
* [[DAQ_Checkout_test|Parity DAQ]] | * [[DAQ_Checkout_test|Parity DAQ]] | ||
* [https://wiki.jlab.org/tegwiki/index.php/Hut_Remote_Power_Map Remote power strips] | * [https://wiki.jlab.org/tegwiki/index.php/Hut_Remote_Power_Map Remote power strips] | ||
** [https://prex.jlab.org/wiki/index.php/HRS_DAQ_for_Q2,_Optics counting mode DAQ] | ** [https://prex.jlab.org/wiki/index.php/HRS_DAQ_for_Q2,_Optics counting mode DAQ] | ||
* [https://hallaweb.jlab.org/tech/Detectors/public_html//hall_a/controls/ioc_portserver_reboot_locations.htm rebooting IOCs] | * [https://hallaweb.jlab.org/tech/Detectors/public_html//hall_a/controls/ioc_portserver_reboot_locations.htm rebooting IOCs] | ||
+ | |||
+ | == Polarization == | ||
+ | * [[Moller Pre-requisite Procedure]] | ||
+ | * [[Moller Procedure]] | ||
+ | * [https://hallaweb.jlab.org/wiki/index.php/Compton Compton Polarimeter], [[Compton_DAQ_HOWTO|DAQ How-tos]] | ||
== Fall 2016 HOWTO == | == Fall 2016 HOWTO == |
Latest revision as of 11:33, 8 September 2020
PREX Main<< Information for Shift Takers << Shift Leader
Overview of Shift Tasks
- Ask the expert (back room) if something is unclear.
- Start / stop runs using the Parity DAQ (apar@adaq1). Keep runs <430 K events or ~0.5 hour at 240 Hz.
- Verify that Charge Asymmetry feedback is running. The data are practically useless if not.
- Verify that Beam Modulation is running
- Look at the Panguin ("online analyzer") plots
- Analyze ("fast prompt") each run and review the prompt plots.
- (new, Aug 19) Run the Compton DAQ
- (new, Feb 28) Run the Compton Counting Mode DAQ
Taking Data
- Starting CODA
- Starting a Run
- Starting the Compton CODA
- Starting, Ending & Analyzing a Compton Run
- Starting the Compton Counting Mode DAQ
- Taking a run
- Online analysis How-To
- HRS_DAQ
- Podd Analysis for Q2, Optics
- Take a spot++ run (High current or low current)
- How to go to cavity lock with low current - this is NOT required for CREX
- Doing a calibration run
- Taking MAIN detector Counting Run (Alignment Check)
PREX Collimator (Septum Temperatures)
Magnets
Target
- TargetOperation
- How to Find the 90-Degree C-Hole
- How to establish beam on a lead target
- Thermally break-in the target in case of long beam down
Detectors
- Trouble-shooting the High Voltage GUI
- Checking the GEM Gas panel
- Checking the HV
- Check-list For taking Counting runs and Going back to Production
Fast Feedback
- If FFB broken badly, execute Plan B. FFB_troubleshooting
Reporting
Parity
- Parity Aq feedback
- Flipping Insertable Half Wave Plate (IHWP) state
- Doing a PITA scan
- History - CREX
Monitoring
- Alarm Handler
- Scalar GUI
- Wall screen
- Panguin
- Responding to Alarms
- HallA Tools
- Strip chart
- Check the raster
- Monitoring the Compton Rates
Beam Modulation
Re-initializing
- Computers
- Detectors
- Magnets
- Recovering from Power Outage
- OLD Coming back from no beam
- NEW Establishing High Current on a Calcium Target
- Parity DAQ
- Remote power strips
- rebooting IOCs
Polarization
Fall 2016 HOWTO
- Info about how to run the DAQ, analyze data, etc: Fall 2016 HOWTO