PREX/CREX Dec 18 2017 11:00am EDT

From PREX Wiki
Jump to navigationJump to search

Back to Main Page >> PREX/CREX_Teleconferences

previous meeting << >> following meeting


Logistic information

 BlueJeans calling instructions:
 Toll-Free Number (U.S.&  Canada):  888-240-2560
 International toll number:         408-740-7256
 Bluejeans CODE:                  847 917 938
 Bluejeans link: https://bluejeans.com/847917938
 Offline room:   CEBAF Center F227

Agenda

  1. Corrector magnets: Ciprian docDBpage drawing1 drawing2 drawing3 drawing4
    • CG: looks like it would be impossible to place any of these correctors after the 8in gate valve. Will talk to Robin to better understand their thinking.
    • KP: plan should be to design a shielded beamline (either replace the current one or shield the current one) if correctors can't work.
  2. FLUKA simulation update: Victoria docDBpage
    • VO: cross checks: power deposited (agrees with G4 within 10%) and comparisons with Qweak W plug (~same order of magnitude). CG: the Qweak plug agreement is relatively ok according to RadCon (George K)
    • VO: added the stainless steel box which provides some additional shielding. Still need to add DS flange and that will provide some self shielding.
    • VO: might be interested in looking at offset beam. CG: we should focus on the center first. KP: the power sensitivity is about 10% for 1 mm offset
    • VO: 30cm from source and 100mRem is high rad area
    • VO: look at electronics damage or boundary dose.

Attendance

Tyler K, Dave G, Sanghwa P, Ciprian G, Adam Z, Bob M, David A, Victoria O, Kent P, Ryan R, Seamus R, Dustin M, Jay B, Cameron C, Devi , Tao Y, Caryn P, Paul S, Guido U, Silviu D,

Excused: